OSHA Inspection: UNIVERSAL COMPONENT CORPORATION

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of UNIVERSAL COMPONENT CORPORATION in 320 WEST MAIN STREET, BRANFORD, CT 06405 (NAICS 321214). OSHA activity number 334958998.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Universal Component Corporation — free Get an email when a new federal OSHA severe-injury report for Universal Component Corporation is published. One employer, no account, unsubscribe in one click.
Site address
320 WEST MAIN STREET
City
BRANFORD
State
CT
ZIP
06405
Mailing
320 WEST MAIN STREET, BRANFORD, CT 06405
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321214
Employees
18
Ownership type
A

3 citations on file for this inspection.

1910.134 E01

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Jul 30, 2012
Abate by
Sep 11, 2012
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1910.134(e)(1):     The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    Factory: Employees were required to wear an N95 respirator while performing work using the MiTek Cyber saw and the MiTek Smart Set saw and none had been provided a medical evaluation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3300

1910.134 F02

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jul 30, 2012
Abate by
Sep 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2):     The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter:    Factory: Employees were required to wear an N95 respirator while performing work using the MiTek Cyber saw and the MiTek Smart Set saw and none had been fit tested prior to initial use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 30, 2012
Abate by
Sep 11, 2012
Penalty
Initial $4,400 · Current $3,000 Reduced
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    Factory: All circuit breakers within electrical panel A located on the west wall of the factory were not legibly marked to indicate their purpose.