Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARTSON-KENNEDY CABINET TOP CO. INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARTSON-KENNEDY CABINET TOP CO. INC in 10115 LORRAINE ROAD, GULFPORT, MS 39503 (NAICS 337110). OSHA activity number 334979788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hartson-Kennedy Cabinet TOP CO. INC — free Get an email when a new federal OSHA severe-injury report for Hartson-Kennedy Cabinet TOP CO. INC is published. One employer, no account, unsubscribe in one click.
Site address
10115 LORRAINE ROAD
City
GULFPORT
State
MS
ZIP
39503
Mailing
10115 LORRAINE ROAD, GULFPORT, MS 39506
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
52
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 25 exposed
Issued
Aug 20, 2012
Abate by
Jun 16, 2014
Penalty
Initial $3,825 · Current $2,295 Reduced
OSH ACT of 1970 Section (5)(a)(1):     Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to combustible dust explosion, deflagration, or other fire hazards while working at or near dust collection system which were not adequately designed to prevent or minimize employee exposure in the event of a deflagraion or other uncontrolled fire event:    a) End of the Bar line - On or about June 27, 2012, employees were exposed to combustible dust fires and explosion hazards because the inside Torit dust collector system was not provided with adequate deflagration venting and suppression system to prevent and control fires and explosion hazards. The discharge chute was not grounded and bonded to the receiving trash container. The lab results from SLTC confirmed that the dust sample was a Class II dust and was explosive. The Hartmann test gave a Kst value which also determined the sample to be explosive.    b) Main outside dust collector system and ducts - On or about June 27, 2012, employees were exposed to combustible dust fires and explosion hazards because the outside dust collector system and inside ducts were not provided with adequate deflagration control, suppression systems, and isolation devices to prevent and control fires and explosion hazards. The discharge chute was not grounded and bonded to the receiving trash container. The lab results from SLTC confirmed that the dust sample was a Class II dust and was explosive. The Hartmann test gave a Kst value which also determined the sample to be explosive.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.22 A01

Serious Gravity 1 2 instances 5 exposed
Issued
Aug 20, 2012
Abate by
Nov 15, 2012
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a) Trim saw at the end of the Bar line - On or about June 27, 2012, employees were exposed to combustible dust fires because the dust collector had a build-up of dust on the metal frame and electrical boxes nearby. The wood dust on the floor around and under the trim saw was not being collected by the dust collector.    b) Outside dust collector system - On or about June 27, 2012, employees were exposed to combustible dust fires because the dust under the dust collector and trash dumpster had build-up on the ground.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.147 C04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 20, 2012
Abate by
Oct 2, 2012
Penalty
Initial $3,060 · Current $1,836 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) At the facility - On or about June 27, 2012, employees were exposed to the unexpected release of hazardous energy because the employer had not developed and documented specific lockout/tagout procedures for controlling hazardous energy.
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060

1910.147 C06 I

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 20, 2012
Abate by
Oct 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:    a) At the facility - On or about June 27, 2012, employees were exposed to the unexpected release of hazardous energy because the employer did not conduct and certify periodic inspections of lockout / tagout procedures of specific machinery or equipment to assure that the lockout/tagout procedures were being followed and were correct.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 C02 VI A

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 20, 2012
Abate by
Oct 2, 2012
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.178(c)(2)(vi)(a):     The employer did not provide powered industrial trucks designated as EX for use in an atmosphere in which combustible dust is or may be in suspension continuously, intermittently, or periodically under normal operating conditions, in quantities sufficient to produce explosive or ignitable mixtures, or where mechanical failure or abnormal operation of machinery or equipment might cause such mixtures to be produced.    a) Trim saw at the end of the Bar line - On or about June 27, 2012, employees were exposed to fires and explosions hazards because the Nissan LP fork truck, model MCUGL02F36LV, Type LP was not rated for the Class II hazardous location.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 20, 2012
Abate by
Sep 11, 2012
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS) (DESCRIBE HAZARD(S) WHERE NECESSARY)    a) At the core builder - On or about June 27, 2012, an emplloyee was exposed to injuries from an air gun that was used for cleaning equipment with a nozzle pressure of 55 p.s.i.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.307 C

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 20, 2012
Abate by
Oct 24, 2012
Penalty
Initial $3,060 · Current $1,836 Reduced
29 CFR 1910.307(c):     Equipment, wiring methods, and installations of equipment in hazardous Class II locations were not intrinsically safe, approved for the hazardous Class II location, or safe for the hazardous Class II location:    a) At the end of the Bar line - On or about June 27, 2012, employees were exposed to combustible dust fires because the electrical equipment next to the dust collector and trim saw was not rated for the Class II location. The Salt Lake Testing Center, SLTC, determined the dust sample to be classified as a Class II combustible dust.
Recent events (2)
  • — I (S) $1836
  • — Z (S) $3060

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Aug 20, 2012
Abate by
Oct 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) In shipping - On or about June 27, 2012, an employee was exposed to electrical hazards because a relocatable power tap (RLPT) was plugged into another RLPT and not directly into a permanent receptacle.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Hartson-Kennedy Cabinet TOP CO. INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334979788.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.