NEW PHILADELPHIA, OH —
OSHA Inspection: MONRO MUFFLER, BRAKE AND SERVICE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MONRO MUFFLER, BRAKE AND SERVICE in 214 SOUTH BROADWAY, NEW PHILADELPHIA, OH 44663 (NAICS 811111). OSHA activity number 335023180.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONRO MUFFLER, BRAKE AND SERVICE
- Site address
- 214 SOUTH BROADWAY
- City
- NEW PHILADELPHIA
- State
- OH
- ZIP
- 44663
- Mailing
- 200 HOLLENDER PARKWAY, ROCHESTER, NY 14615
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 E01
- Issued
- Oct 24, 2012
- Abate by
- May 24, 2013
- Penalty
- Initial $5,500 · Current $5,500
General-duty citation text
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard. a) At the time of inspection, in the tire stock area, the most interior walkway does not have horizontal railings at the correct heights exposing employees to fall hazards. b) At the time of inspection, in the tire stock area, the center walkway does not have horizontal railings at the correct heights exposing employees to fall hazards. c) At the time of inspection, in the tire stock area, the exterior walkway does not have horizontal railings at the correct heights exposing employees to fall hazards.
Recent events (3)
- — F (O) $5500
- — C (S) $5500
- — Z (S) $5500
1910.147 C06 I
- Issued
- Oct 24, 2012
- Abate by
- Jun 14, 2013
- Penalty
- Initial $5,500 · Current $3,850 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) At the Monro Muffler, Brake and Service shop, located on South Broadway in New Philadelphia, Ohio, the employer did not conduct an annual or more frequent inspection of the energy control procedures by each authorized personnel to ensure that they were properly implemented during the repair and service work on the following equipment but not limited to: Air Compressor, Automotive Lifts, Oxygen Generators, Air Filters, Tire Changer, and Air Condition Refrigerant Recovery Machine.
Recent events (3)
- — F (S) $3850
- — C (S) $5500
- — Z (S) $5500
1910.305 G01 IV
- Issued
- Oct 24, 2012
- Penalty
- Initial $3,300 · Current $3,300
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: As a substitute for the fixed wiring of a structure; a) At the time of inspection, at the alignment machine station, an approximately 10 foot black extension cord servicing an alignment machine computer and printer, was used as a substitute for fixed wiring exposing employees to a fire hazard.
Recent events (3)
- — F (O) $3300
- — C (S) $3300
- — Z (S) $3300
More inspections at Monro Muffler, Brake and Service
View Monro Muffler, Brake and Service's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335023180.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.