Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: MONRO MUFFLER, BRAKE AND SERVICE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MONRO MUFFLER, BRAKE AND SERVICE in 214 SOUTH BROADWAY, NEW PHILADELPHIA, OH 44663 (NAICS 811111). OSHA activity number 335023180.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Monro Muffler, Brake and Service — free Get an email when a new federal OSHA severe-injury report for Monro Muffler, Brake and Service is published. One employer, no account, unsubscribe in one click.
Site address
214 SOUTH BROADWAY
City
NEW PHILADELPHIA
State
OH
ZIP
44663
Mailing
200 HOLLENDER PARKWAY, ROCHESTER, NY 14615
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.23 E01

Other-than-serious 3 instances 4 exposed
Issued
Oct 24, 2012
Abate by
May 24, 2013
Penalty
Initial $5,500 · Current $5,500
29 CFR 1910.23(e)(1):     A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard.    a) At the time of inspection, in the tire stock area, the most interior walkway does not have horizontal railings at the correct heights exposing employees to fall hazards.    b) At the time of inspection, in the tire stock area, the center walkway does not have horizontal railings at the correct heights exposing employees to fall hazards.    c) At the time of inspection, in the tire stock area, the exterior walkway does not have horizontal railings at the correct heights exposing employees to fall hazards.
Recent events (3)
  • — F (O) $5500
  • — C (S) $5500
  • — Z (S) $5500

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 24, 2012
Abate by
Jun 14, 2013
Penalty
Initial $5,500 · Current $3,850 Reduced
29 CFR 1910.147(c)(6)(i):     The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.      a) At the Monro Muffler, Brake and Service shop, located on South Broadway in New Philadelphia, Ohio, the employer did not conduct an annual or more frequent inspection of the energy control procedures by each authorized personnel to ensure that they were properly implemented during the repair and service work on the following equipment but not limited to: Air Compressor, Automotive Lifts, Oxygen Generators, Air Filters, Tire Changer, and Air Condition Refrigerant Recovery Machine.
Recent events (3)
  • — F (S) $3850
  • — C (S) $5500
  • — Z (S) $5500

1910.305 G01 IV

Other-than-serious 1 instance 4 exposed
Issued
Oct 24, 2012
Penalty
Initial $3,300 · Current $3,300
29 CFR 1910.305(g)(1)(iv)(A):     Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:      As a substitute for the fixed wiring of a structure;    a) At the time of inspection, at the alignment machine station, an approximately 10 foot black extension cord servicing an alignment machine computer and printer, was used as a substitute for fixed wiring exposing employees to a fire hazard.
Recent events (3)
  • — F (O) $3300
  • — C (S) $3300
  • — Z (S) $3300

View Monro Muffler, Brake and Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335023180.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.