NEW YORK, NY ·
OSHA Inspection: ALAN PARTY & TENT RENTALS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALAN PARTY & TENT RENTALS INC. in 601 W 122 ST, NEW YORK, NY 10027 (NAICS 532299). OSHA activity number 335030185.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALAN PARTY & TENT RENTALS INC.
- Site address
- 601 W 122 ST
- City
- NEW YORK
- State
- NY
- ZIP
- 10027
- Mailing
- 450 HUYLER ST, SUITE 101, SOUTH HACKENSACK, NJ 07606
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 532299
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 C01
- Issued
- Nov 6, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open sided floor, platform or runway 4 or more feet above adjacent floor or ground level was not guarded with a standard guardrail or the equivalent on all open sides to protect employees from fall hazard: Location: 601 W 122 Street, New York, N.Y. On or about 5/10/2012 a) Employees were exposed to falling 27 ft from the roof when using stepladders to install a tent on a rooftop patio. The 6 ft stepladder employees were using was unstable and employees climbed high up on the ladder to where they can fall over the roof railing. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.25 D01 I
- Issued
- Nov 6, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.25(d)(1)(i): Ladders were not maintained in a good condition at all times; with moveable parts not having undue play: Location: 601 W 122 Street, New York, N.Y. On or about 5/10/2012 a) The 6 foot A-frame stepladder used by employees had excessive wear causing it to be unstable. The ladder had worn spreaders, was overly flexible, warning labels were worn off. Employees were exposed to fall hazards when using the ladder during installation of tent on a rooftop patio. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1910.25 D01 X
- Issued
- Nov 6, 2012
- Abate by
- Nov 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.25(d)(1)(x): The employer did not ensure that ladders shall be inspected frequently and those which have developed defects shall be withdrawn from service for repair or destruction and tagged or marked as Dangerous, Do Not Use: Location: 601 W 122 Street, New York, N.Y. On or about 5/10/2012 a) The employer did not inspect and remove the 6 ft stepladder from service. The ladder had worn spreaders, was overly flexible, warning labels were worn off. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.25 D02 XII
- Issued
- Nov 6, 2012
- Abate by
- Nov 27, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.25(d)(2)(xii): Tops of ordinary types of stepladders were used as steps: Location: 601 W 122 Street, New York, N.Y. On or about 5/10/2012 a) Employees stood on the upper steps of a 6 ft stepladder, causing the ladder to be unstable. Employee was exposed to falling 27 ft off the roof when the ladder became unstable and tipped over. To get extra height the employee straddled the top of the ladder with one foot on the upper steps (2nd from top step) and the other foot on the bracing on the back of the ladder. Warning labels on the ladder prohibit standing on these upper steps but the labels were worn off. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.25 D02 XX
- Issued
- Nov 6, 2012
- Abate by
- Nov 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.25(d)(2)(xx): The employer did not ensure that employees will not stand on the back bracing of the stepladder; The bracing on the back legs of the stepladder is designed solely for increasing stability and not for climbing: Location: 601 W 122 Street, New York, N.Y. On or about 5/10/2012 a) Employees straddled the top of the ladder with one foot on the upper steps (2nd from top step) and the other foot on the bracing on the back of the ladder. The ladder kicked out and the employee fell. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 A02 X
- Issued
- Nov 6, 2012
- Abate by
- Nov 27, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused for example, by sharp corners, projections, and doorways or other pinchpoints: Location: 601 W 122 Street, New York, N.Y. On or about 5/10/2012 a) Employees were exposed to electric shock hazard when installing and using temporary light cables onto the frame of a rental tent. Wire insulation was worn and separated in several instances, exposing the inner wires to damage. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.304 G05
- Issued
- Nov 6, 2012
- Abate by
- Nov 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. 29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. Location: 601 W 122 Street, New York, N.Y. On or about 5/10/2012 a) Employees were exposed to electric shock hazard when installing temporary electric power and light cables on a rental tent that employees were installing. Four plugs (three prong cable plugs) had broken/ missing ground pins. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 532299)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335030185.