FORT GORDON, GA ·
OSHA Inspection: SWING ERECTORS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of SWING ERECTORS, INC. in BUILDING 29702, FORT GORDON, GA 30905 (NAICS 238120). OSHA activity number 335040382.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SWING ERECTORS, INC.
- Site address
- BUILDING 29702
- City
- FORT GORDON
- State
- GA
- ZIP
- 30905
- Mailing
- 1970 POPE ROAD, VILLA RICA, GA 30180
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.351 B02
- Issued
- Jul 16, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.351(b)(2): Welding cable(s) in use were not free from improper repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected: On or about Wednesday June 13, 2012 at building 29702 Fort Gordon, GA; The employees operated a welder machine with damage to the cable at approximately 2 feet 8 inches from the electrode holder. The employees were engaged in welding metal material on the building and the equipment the employees were using operated at approximately 40 DC volts and up to 300 amps of output at the electrode holder. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $2800
1926.351 B04
- Issued
- Jul 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair: On or about Wednesday June 13, 2012 at building 29702 Fort Gordon, GA; The employees operated a welder machine with damage to the cable at the connection at the ground connector on the welding equipment. The employees were engaged in welding metal material on the building and the equipment the employees were using operated at approximately 40 DC volts and up to 300 amps of output at the electrode holder. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $0
1926.351 C06
- Issued
- Jul 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.351(c)(6): All ground connections shall be inspected to ensure that they are mechanically strong and electrically adequate for the required current. On or about Wednesday June 13, 2012 at building 29702 Fort Gordon, GA; The employer failed to inspect the ground cable connection on the welder equipment the employees were operating with damage to the cable at the connection at the ground connector on the welding equipment and to the metal material use to ground the equipment. The employees were engaged in welding metal material on the building and the equipment the employees were using operated at approximately 40 DC volts and up to 300 amps of output at the electrode holder. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238120)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335040382.