OSHA Inspection: STRUCTURES UNLIMITED, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of STRUCTURES UNLIMITED, INC. in 40 RIVER ROAD SUITE 1, BOW, NH 03304 (NAICS 332311). OSHA activity number 335071387.

Watch Structures Unlimited, INC. — free Get an email when a new federal OSHA severe-injury report for Structures Unlimited, INC. is published. One employer, no account, unsubscribe in one click.
Site address
40 RIVER ROAD SUITE 1
City
BOW
State
NH
ZIP
03304
Mailing
40 RIVER ROAD SUITE 1, BOW, NH 03304
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
34
Ownership type
A

3 citations on file for this inspection.

1910.215 B09

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2975.00
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a  Assembly area - Dayton 6" bench grinder had no tongue guard or other means to guard the top part of the abrasive wheel opening greater than one quarter inch.
Recent events (1)
  • — Z (S) $2975

1910.22 A01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.    Assembly area - Floor in front of bench grinder was littered with wire insulation and cables creating a tripping hazard.
Recent events (1)
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a.  Bench grinder bolted to bench was attached to drop cord by cord and plug.
Recent events (1)
  • — Z (O) $0

View STRUCTURES UNLIMITED, INC.'s full OSHA safety record →