Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAPITAL ELECTRIC CONSTRUCTION CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CAPITAL ELECTRIC CONSTRUCTION CO., INC. in 3201 FAIRFAX TRAFFICWAY, KANSAS CITY, KS 66115 (NAICS 811310). OSHA activity number 335071585.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capital Electric Construction CO., INC. — free Get an email when a new federal OSHA severe-injury report for Capital Electric Construction CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
3201 FAIRFAX TRAFFICWAY
City
KANSAS CITY
State
KS
ZIP
66115
Mailing
600 BROADWAY SUITE 600, KANSAS CITY, MO 64105
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
373
Ownership type
A

3 citations on file for this inspection.

1926.21 B02

Other-than-serious 1 instance 4 exposed
Issued
Dec 19, 2012
Penalty
Initial $5,000 · Current $1,500 Reduced
29 CFR 1926.21(b)(2):     The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
Recent events (3)
  • — F (O) $1500
  • — C (S) $5000
  • — Z (S) $5000

1910.335 A01 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 19, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.335(a)(1)(i):  Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:      On or about July 1, 2012, employee(s) and subcontractor were exposed to electrocution, electric shock, and arc flash explosion hazards due to no personal protective equipment being worn while preparing substations 3A and 3B, feeders A-6 for cleaning.  The substations were rated at 1,200 amps and 13,800 volts.  The following actions were taken without any personal protective equipment being worn:      (a) using a hot stick and voltage tester inside the cabinets of substations 3A and 3B, feeder A - 6.      (b) applying safety grounds to substations 3A and 3B, feeder A - 6
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.333 B02 IV B

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 19, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.333(b)(2)(iv)(B):  A qualified person did not used adequate testing to verify that all circuit elements and equipment parts are deenergized:       On or about July 1, 2012 an employee in the process of cleaning the inside components of substation 3B, feeder A-6 in transformer room #3 was exposed to electrocution, electric shock, and arc flash explosion hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000