Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SLAYTER, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SLAYTER, LLC in 200 MCKEITHEN DR., ALEXANDRIA, LA 71303 (NAICS 484121). OSHA activity number 335077194.

Watch Slayter, LLC — free Get an email when a new federal OSHA severe-injury report for Slayter, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SLAYTER, LLC
Site address
200 MCKEITHEN DR.
City
ALEXANDRIA
State
LA
ZIP
71303
Mailing
200 MCKEITHEN DR., ALEXANDRIA, LA 71303
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484121
Employees
11
Ownership type
A

13 citations on file for this inspection.

1910.22 A02

Other-than-serious 1 instance 37 exposed
Issued
Sep 14, 2012
Abate by
Sep 28, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.22(a)(2): The floor of every workroom shall be maintained in a clean and, so far as possible, a dry condition. Where wet processes are used, drainage shall be maintained, and false floors, platforms, mats, or other dry standing places should be provided where practicable.      On or before July 9, 2012 the floor of the front of the mechanic shop was not maintained to provide drainage of rainwater.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2100

1910.147 C07 I A

Serious Gravity 5 10 instances 2 exposed
Issued
Sep 14, 2012
Abate by
Oct 14, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.      a) The employer did not explain all energy sources applicable to Cram-A-Lot, Selco, and Will pak Baler cardboard compressors. The employer did not identify stored energy sources such as that existing in the cardboard compressors. The employer did not identify and communicate the necessary methods and means to control this energy.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.151 C

Serious Gravity 1 1 instance 10 exposed
Issued
Sep 14, 2012
Abate by
Oct 14, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.      a) Mechanic shop: Employees did not have suitable facilities for quick drenching or flushing of the eyes or skin.  Employees handle chemicals such as, Astro I.  Employees transfer the product(s) from a 55 gallon barrel to secondary containers for dilution. The diluted solution(s) is used to clean chrome on trucks.  The Astro I is a chrome cleaner that contains hydroflouric acid.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.178 L01 I

Other-than-serious 3 instances 10 exposed
Issued
Sep 14, 2012
Abate by
Oct 14, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).      a) Mechanic shop; The employer failed to ensure employees operating Hyster Forklifts were adequately instructed in safe operations of the truck, such as, a review of the operators manual and importance of safety features.  Employees disconnected the back-up alarms on the forklifts while operating them.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1910.212 A03 II

Serious Gravity 1 2 instances 8 exposed
Issued
Sep 14, 2012
Abate by
Sep 28, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.      a) Mechanic shop; Two drill press did not have a guard around the bit to prevent a point of operation injury:        1. JET drill press, Model#: JMD-18, S/N: 7178312        2. 8" Delta drill press
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.212 A05

Other-than-serious 1 instance 1 exposed
Issued
Sep 14, 2012
Abate by
Sep 25, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch.      a) Cardboard shop; A fan used for cooling purposes was observed missing the guard and had openings larger than 1/2 inch. The fan has an approximately 11 inch opening on the front and side. This condition exposed employees to an amupation hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1910.212 B

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 14, 2012
Abate by
Sep 21, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.      a) Mechanic shop: A Delta Shopmaster Bench Grinder pedestal was not secured from moving or walking during use.  Inadvertent movement of the grinder could cause work piece slippage and loss of control resulting in employee injury and/or abrasive wheel breakage.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.253 B04 III

Serious Gravity 1 2 instances 8 exposed
Issued
Sep 14, 2012
Abate by
Sep 15, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.      a) Mechanic shop; Compressed oxygen cylinders were stored with acetylene gas cylinders on carts that did not have a fire resistant barrier.    b) Cylinder storage room in rear of mechanic shop; Compressed oxygen cylinders and acetylene gas cylinders were stored together. The cylinders did not have a fire resistant barrier to seperate them and the cylinders were not seperated by at  least 20 feet.    These conditions exposed employees to a fire hazard.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.305 B01 II

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 14, 2012
Abate by
Sep 21, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.      a) Mechanic shop; An electrical panelboard had four (4) uncovered circuit breaker openings that exposed employees to possible contact with live electrical conductors and the hazard of electrical shock.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.305 G02 II

Other-than-serious 1 instance 1 exposed
Issued
Sep 14, 2012
Abate by
Sep 17, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.      a) Cardboard shop; a electrical powercord was spliced and used to power a fan. The powercord was plugged in to a powertap and spliced to the wires of the fan. The splicing exposed bare wiring exposing employees to an electric shock hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2100

1910.1200 G08

Deleted Serious Gravity 1 4 instances 8 exposed
Issued
Sep 14, 2012
Abate by
Oct 4, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.1200(g)(8): The employer shall maintain in the workplace copies of the required material safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access, microfiche, and other alternatives to maintaining paper copies of the material safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)      a) Mechanic shop; The employer did not maintain copies of material safety data sheets at the location.  Employees use chemicals such as, but not limited to, diesel, oil, degreaser, and Astro I acid chrome cleaner.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1904.29 B01

Other-than-serious 5 instances 37 exposed
Issued
Sep 14, 2012
Abate by
Oct 14, 2012
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1904.29(b)(1): A Log of Work-Related Injuries and Illnesses (OSHA Form 300) and the Summary of Work-Related Injuries and Illnesses (OSHA Form 300A) were not kept by the establishment:      The employer did not record work-related injuries and illnesses on the OSHA Form 300, nor did the employer complete the annual summary of injuries and illnesses on the OSHA Form 300A.  The employer did not have these required forms for recording injuries and illnesses for year(s) 2012, 2011, 2010, 2009 and 2008.  The forms are required to be maintained for five (5) years following the end of the calendar year that these records cover.
Recent events (2)
  • — I (O) $0
  • — Z (O) $700

1910.1200 F06

Other-than-serious 1 instance 4 exposed
Issued
Sep 14, 2012
Abate by
Sep 15, 2012
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1910.1200(f)(6): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:      a) Mechanic shop: The employer did not ensure all containers were properly labeled.  The condition applies to a 55 gallon drum that is labeled hydraulic fluid but is used to store diesel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335077194.