HAMPTON, VA —
OSHA Inspection: CENTURY CONCRETE
Unprogrammed Other inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Other health inspection of CENTURY CONCRETE in BUILDING 361 LANGLEY AIR FORCE BASE, HAMPTON, VA 23665 (NAICS 238140). OSHA activity number 335085783.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTURY CONCRETE
- Site address
- BUILDING 361 LANGLEY AIR FORCE BASE
- City
- HAMPTON
- State
- VA
- ZIP
- 23665
- Mailing
- 1364 AIR RAILL AVE., VIRGINIA BEACH, VA 23452
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.50 G
- Issued
- Aug 14, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.50(g): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a.) Century Concrete, Langley Air Force Base, Building 361: On or about 07/09/12, the employer did not provide an emergency eyewash facility for employees exposed to the corrosive Kaufman SureGrout and the corrosive Lehigh Portland Cement.
Recent events (2)
- — I (S) $0
- — Z (S) $3000
1926.404 B01 II
- Issued
- Aug 14, 2012
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere were not a part of the permanent wiring of the building or structure, or receptacles on a portable generator rated more than 5kW, and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a.) Century Concrete, Langley Air Force Base, Building 361: On or about 07/11/12, employees using the Dewalt circular saw powered by the Multiquip 6000 Watt portable generator were not protected by the use of ground fault circuit interrupters.
Recent events (2)
- — I (S) $3000
- — Z (S) $3000
1926.403 B02
- Issued
- Aug 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a.) Century Concrete, Langley Air Force Base, Building 361: On or about 07/11/12, the employer did not ensure that equipment was used in accordance with instructions in the listing and labeling: in that, the Dewalt circular saw was being powered by daisy chained extension cords.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Century Concrete
View Century Concrete's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335085783.