Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RPN TRIM, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RPN TRIM, INC. in 4529 THORNBERRY ST., FREDERICK, CO 80504 (NAICS 238130). OSHA activity number 335089991.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RPN Trim, INC. — free Get an email when a new federal OSHA severe-injury report for RPN Trim, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RPN TRIM, INC.
Site address
4529 THORNBERRY ST.
City
FREDERICK
State
CO
ZIP
80504
Mailing
7211 BRYANT ST., WESTMINSTER, CO 80030
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.404 F06

Other-than-serious 2 instances 2 exposed
Issued
Jul 17, 2012
Abate by
Jul 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a)  RPN Trim, Inc. at 4529 Thornberry Street, Frederick, CO 80504:  On or before July 7, 2012, the employer did not ensure that two 120 volt Skilsaws used to cut siding were grounded in that both saws were missing their ground plugs. The skilsaws were not double insulated but were used on a ground fault circuit interrupter (GFCI).  Condition exposed employees to the electrical shock hazards.
Recent events (1)
  • — Z (O) $0

1926.416 E01

Other-than-serious 1 instance 2 exposed
Issued
Jul 17, 2012
Abate by
Jul 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:    a)  RPN Trim, Inc. at 4529 Thornberry Street, Frederick, CO 80504:  On or before July 7, 2012, the employer allowed employees to use an extension cord with the outer insulation separated from the plug.  Condition exposed employees to electrical shock hazards.
Recent events (1)
  • — Z (O) $0

View RPN Trim, INC.'s full OSHA safety record →