ELKO, NV —
OSHA Inspection: DEPARTMENT OF COMMERCE - NATIONAL WEATHER SERVICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEPARTMENT OF COMMERCE - NATIONAL WEATHER SERVICE in NWS - NOAA 3720 PARADISE DRIVE, ELKO, NV 89801 (NAICS 519190). OSHA activity number 335096582.
Where did this inspection happen?
- Establishment
- DEPARTMENT OF COMMERCE - NATIONAL WEATHER SERVICE
- Site address
- NWS - NOAA 3720 PARADISE DRIVE
- City
- ELKO
- State
- NV
- ZIP
- 89801
- Mailing
- 3720 PARADISE DRIVE, ELKO, NV 89801
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 519190
- Employees
- 23
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.36 G02
- Issued
- Nov 23, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. (a) At the National Weather Service, NOAA-Elko, exit access was obstructed by desks and traffic cones.
Recent events (1)
- — Z (S) $0
1910.37 B02
- Issued
- Nov 23, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit". (a) At the National Weather Service, NOAA-Elko, the electrical exit door was not marked "EXIT".
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Nov 23, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. (a) At the National Weather Service, NOAA-Elko, warning coordination meteorologist area, the relocatable power tap was plugged into an extension cord not directly to the wall outlet.
Recent events (1)
- — Z (S) $0
1910.1200 E01 I
- Issued
- Nov 23, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet. (a) At the National Weather Service, NOAA-Elko, the employer did not maintain a complete inventory of all chemicals in the work place to include: Home-lite charcoal lighter fluid, xtreme goo gone solvent remover, home-lite bleach, etc,.
Recent events (1)
- — Z (S) $0
1910.1200 G08
- Issued
- Nov 23, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace. (a) At the National Weather Service, NOAA-Elko, copies of material safety data sheets were not kept and made available in the work place for Home-lite charcoal lighter fluid, xtreme goo gone solvent remover, home-lite bleach, etc,.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 519190)
More inspections in NV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335096582.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.