EAGLE, ID ·
OSHA Inspection: ROBERT J. DILGARD, DBA DILGARD CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROBERT J. DILGARD, DBA DILGARD CONSTRUCTION in 1716 W. COLCHESTER DR., EAGLE, ID 83616 (NAICS 238130). OSHA activity number 335127189.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROBERT J. DILGARD, DBA DILGARD CONSTRUCTION
- Site address
- 1716 W. COLCHESTER DR.
- City
- EAGLE
- State
- ID
- ZIP
- 83616
- Mailing
- 2193 W. RATTLESNAKE DR., MERIDIAN, ID 83642
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 2, 2012
- Abate by
- Nov 5, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) North facing side of the house: on May 10, 2012, and at times prior thereto, an employee toe nailing trusses while standing on the top of a wall, was without a means of fall protection. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1926.503 A02 III
- Issued
- Nov 2, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used. a) North facing side of the house: on or about May 10, 2012 and at times prior thereto, the employer did not provide employees performing residential framing/sheathing work with training or instruction associated with the hazard of falls. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1051 A
- Issued
- Nov 2, 2012
- Abate by
- Nov 9, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a) North facing side of the house , on or about May 10, 2012, and at times prior thereto, an employee exiting from the top of a ten ft. high wall was not provided with a ladder to gain access to the ground. Note: Abatement certification IS required for this item.