Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMPLETE CONTRACTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMPLETE CONTRACTING in 930 MAPLE ROAD, AMHERST, NY 14226 (NAICS 238350). OSHA activity number 335137386.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Complete Contracting — free Get an email when a new federal OSHA severe-injury report for Complete Contracting is published. One employer, no account, unsubscribe in one click.
Site address
930 MAPLE ROAD
City
AMHERST
State
NY
ZIP
14226
Mailing
6142 TACHI DRIVE, NEWFANE, NY 14108
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.300 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 15, 2012
Penalty
Initial $1,200 · Current $500 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:    a) On or about 7/11/12, at the site of Amherst, NY. The table saw was not equipped with guards when cutting 3/4 inch plywood.    No Abatement Certification Required
Recent events (2)
  • — I (S) $500
  • — Z (S) $1200

1926.404 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 15, 2012
Penalty
Initial $1,200 · Current $500 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.    a) On or about 7/11/12, at the site of Amherst, NY. Ground fault circuit interrupters were not provided for tools that drew power through a flexible cord.    No Abatement Certification Required
Recent events (2)
  • — I (S) $500
  • — Z (S) $1200

1926.404 F06

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 15, 2012
Penalty
Initial $1,200 · Current $500 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) On or about 7/11/12, at the site of Amherst, NY. The flexible cord, that provided power for tools, lacked the ground prong.    No Abatement Certification Required
Recent events (2)
  • — I (S) $500
  • — Z (S) $1200

View Complete Contracting's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335137386.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.