Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALLIED DIES, INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ALLIED DIES, INC in 800 CASHMAN DRIVE, CHIPPEWA FALLS, WI 54729 (NAICS 333514). OSHA activity number 335138384.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Allied Dies, INC — free Get an email when a new federal OSHA severe-injury report for Allied Dies, INC is published. One employer, no account, unsubscribe in one click.
Establishment
ALLIED DIES, INC
Site address
800 CASHMAN DRIVE
City
CHIPPEWA FALLS
State
WI
ZIP
54729
Mailing
800 CASHMAN DRIVE, CHIPPEWA FALLS, WI 54729
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333514
Employees
37
Ownership type
A

5 citations on file for this inspection.

1910.106 E09 III

Serious Gravity 1 3 instances 30 exposed
Issued
Oct 11, 2012
Abate by
Oct 22, 2012
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:         (a) Throughout the production area; Shop rags soaked with flammable/combustible liquids were not disposed of as                 required by this standard, in that:               i. Flammable container were not emptied daily,             ii. Metal flammable containers were not closed,             iii. Acetone soaked toilet paper was thrown into open-air plastic garbage cans
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.213 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 11, 2012
Abate by
Oct 18, 2012
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material.         (a) Shipping area; The lower portion of an exposed blade on a 10-inch radial arm saw was not guarded.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.303 G01 II

Serious Gravity 1 2 instances 2 exposed
Issued
Oct 11, 2012
Abate by
Oct 18, 2012
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:         (a) Production area; Materials were stored less than 30 inches in front of electrical equipment, in that;              i. Die heating adapters were stored on top of a 480v electrical panel,              ii. A rolling step ladder and welding screen were stored less than 30 inches in front of a 480v electrical                    disconnect for the air compressor.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.305 J01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 11, 2012
Abate by
Oct 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact:         (a) Die heating area; Physical guarding was not provided for a four foot long fluorescent light fixture mounted                approximately 7 feet, 6inches above the walking/working surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Oct 11, 2012
Abate by
Oct 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:         (a) Die heating area; An extension cord was used to provide power to a permanently installed 4 foot fluorescent light             fixture.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Allied Dies, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335138384.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.