OSHA Inspection: FALK PRECISION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FALK PRECISION INC. in 5917 FISHER ROAD, EAST SYRACUSE, NY 13057 (NAICS 332710). OSHA activity number 335148581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Falk Precision INC. — free Get an email when a new federal OSHA severe-injury report for Falk Precision INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FALK PRECISION INC.
Site address
5917 FISHER ROAD
City
EAST SYRACUSE
State
NY
ZIP
13057
Mailing
5917 FISHER ROAD, EAST SYRACUSE, NY 13057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
34
Ownership type
A

8 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 2 instances 3 exposed
Issued
Aug 21, 2012
Abate by
Sep 20, 2012
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)  At the establishment, on or about 7/10/12:  There were no specific written procediures for, including, but not limited to a Palletech machine and the Mazak CNC 90119.    Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $1785

1910.147 C06 I

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 21, 2012
Abate by
Sep 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:    a)  At the establishment, on or about 7/10/12:   Annual inspections of the energy control procedures were not conducted and documented to ensure that the procedures and requirements of the standard were being followed.  Employees perform servicing and/or maintenance on various equipment, including but not limited to CNC lathes, CNC milils, press brakes, compressors, Timesaver, shear,  etc.    Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $0

1910.184 I09 IV

Serious Gravity 1 2 instances 2 exposed
Issued
Aug 21, 2012
Abate by
Aug 28, 2012
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.184(i)(9)(iv):  Synthetic web sling(s) with broken or worn stitches were not immediately removed from service:    a)  Air Compressor Area, on or about 7/10/12:  Two nylon slings with broken and worn stitches had not been removed from service.    Abatements certification must be submitted for this item.
Recent events (1)
  • — Z (S) $1785

1910.212 A01

Serious Gravity 1 3 instances 3 exposed
Issued
Aug 21, 2012
Abate by
Sep 20, 2012
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.212(a)(1):     Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:    a)  Lathe Section, on or about 7/10/12:  Rotating chucks on a Jet lathe and Harrison lathe were not guarded.    b)  Mill Section, on or about 7/10/12:  Rotating chuck on a Clausing radial drill was not guarded.    Abatement certification must be submitted for these items.
Recent events (1)
  • — Z (S) $1785

1910.212 A03 II

Serious Gravity 5 2 instances 1 exposed
Issued
Aug 21, 2012
Abate by
Sep 20, 2012
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a)  Press Brake Area, on or about 7/10/12:  Point of operation on an Adira CNC press brake #M90021 and an Adira mechanical press brake #M90022 were not guarded.    Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $2975

1910.242 B

Serious Gravity 1 5 instances 4 exposed
Issued
Aug 21, 2012
Abate by
Sep 20, 2012
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a)  Lathe Section, on or about 7/10/12:  Compressed air used for cleaning purposes measured >100 psi at the Omni turn lathe #M90019, at the Ikegai lathe #M90011, at the Omni lathe #M90047, at the Omni lathe #M90020.    b)  Mill Section, on or about 7/10/12:  Compressed air used for cleaning purposes measured >100 psi at the Mazak mill #M90028.    Abatement certification must be submitted for these items.
Recent events (1)
  • — Z (S) $1785

1910.332 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 21, 2012
Abate by
Sep 20, 2012
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.332(b)(1):     Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:    a)  At the establishment, on or about 7/10/12:  Employees performing troubleshooting, repairs or installing new electrical equipment wre not provided training in regards to safety related work practices and the use of appropriate personal protective equipment.    Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $2975

1910.333 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 21, 2012
Abate by
Sep 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(i):     The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:    a)  At the establishment, on or about 7/10/12:  There were no written safety related work practice program in place to prevent electrical shock or other injuries to employees when working on machines and equipment.    Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $0