CORTLAND, NY ·
OSHA Inspection: F.W. DENNIS STEEPLE JACKS ROOFING SPECIALISTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of F.W. DENNIS STEEPLE JACKS ROOFING SPECIALISTS in UNITED PRESBYTERIAN CHURCH, 25 CHURCH STREET, CORTLAND, NY 13045 (NAICS 238160). OSHA activity number 335175188.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- F.W. DENNIS STEEPLE JACKS ROOFING SPECIALISTS
- Site address
- UNITED PRESBYTERIAN CHURCH, 25 CHURCH STREET
- City
- CORTLAND
- State
- NY
- ZIP
- 13045
- Mailing
- 8483 STATE STREET ROAD, PORT BYRON, NY 13140
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.453 B02 IV
- Issued
- Sep 19, 2012
- Penalty
- Initial $1,760 · Current $1,760
General-duty citation text
29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: a) West side of church, southwest corner, on or about 7-12-12: Two employees were working in an articulating, extensible boom, aerial lift, while standing on the mid rail, exposing the employees to a fall hazard of 50 feet.
Recent events (1)
- · Z (S) $1760
1926.453 B02 V
- Issued
- Sep 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a) West side of church, northwest corner, on or about 7-12-12: Two employees were working in an articulating, extensible boom, aerial lift, without a safety harness or body belt connected, exposing the employee to a fall hazard of 100 feet.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335175188.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.