ORMOND BEACH, FL —
OSHA Inspection: PIONEER CONTRACTING AND RENOVATIONS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PIONEER CONTRACTING AND RENOVATIONS in 712 SOUTH A!A, ORMOND BEACH, FL 32174 (NAICS 238140). OSHA activity number 335190385.
Where did this inspection happen?
- Establishment
- PIONEER CONTRACTING AND RENOVATIONS
- Site address
- 712 SOUTH A!A
- City
- ORMOND BEACH
- State
- FL
- ZIP
- 32174
- Mailing
- PO BOX 265702, DAYTONA BEACH, FL 32116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds were not fully planked or decked between the front uprights and the guardrail supports as follows: a. On or about July 13, 2012, the scaffold platform was not fully planked or decked between the front uprights and the guardrail supports, exposing employees to a 25 feet fall hazard.
Recent events (1)
- — Z (S) $2000
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about July 13, 2012, there were nine scaffold post that did not bear on base plates, mud sills or other adequate firm foundation.
Recent events (1)
- — Z (S) $2000
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a. On or about July 13, 2012, the scaffold platform did not have a ladder or other means of safe access.
Recent events (1)
- — Z (S) $2000
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about July 13, 2012, the scaffold platform did not have a guardrail, exposing employees to a 25 feet fall hazard.
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16 00:00:00
DC MASONRY
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
WINNETKA, IL—2026-07-15 00:00:00
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15 00:00:00
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14 00:00:00
SUDLOW CONCRETE, INC.
More inspections in FL
DELAND, FL—2026-07-16 00:00:00
BALL FABRICS
GAINESVILLE, FL—2026-07-16 00:00:00
WACKY SAUCES LLC
FORT WALTON BEACH, FL—2026-07-16 00:00:00
WASTE MANAGEMENT, INC. OF FLORIDA
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
Source