DOUGLAS, GA —
OSHA Inspection: FAB TEC, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FAB TEC, INC. in 2150 INDUSTRIAL BOULEVARD, DOUGLAS, GA 31533 (NAICS 332999). OSHA activity number 335195996.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FAB TEC, INC.
- Site address
- 2150 INDUSTRIAL BOULEVARD
- City
- DOUGLAS
- State
- GA
- ZIP
- 31533
- Mailing
- 2150 INDUSTRIAL BOULEVARD, DOUGLAS, GA 31533
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 37
- Ownership type
- A
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $3,500 · Current $1,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being crushed and or struck by a falling load. A) At jig 1 area, on or about July 12, 2012, and at times prior to, employees operated 2 ton overhead Jib Cranes with electric hoist to lift materials. The hook used with the hoist did not have a self closing spring operated latch across the throat of the hook to prevent material from accidentally becoming detached from the hook, exposing employees to struck-by falling material. ABATEMENT CERTIFICATION AND DOCUMENTATIONS ARE REQUIRED.
Recent events (2)
- — I (S) $1000
- — Z (S) $3500
1910.22 A01
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $4,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. A) In the Jig 1 area, on or about July 12, 2012, and at times prior to, the work area was littered with materials and trash which made the area not clean, exposing employees to trip and fall hazards. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $1000
- — Z (S) $4200
1910.22 A02
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The floor of every workroom shall be maintained in a clean and, so far as possible, a dry condition. Where wet processes are used, drainage shall be maintained, and false floors, platforms, mats, or other dry standing places should be provided where practicable. A) In the tireshop, on or about July 12, 2012, and at times prior to, the floor was flooded from rain, exposing employees to slip and fall hazards. B) In the sheet metal shop, on or about July 12, 2012, and at times prior to, hydraulic press break leaked hydraulic fluid on the floor, exposing employees to slip and fall hazards. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.37 A03
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. A) In the tireshop, on or about July 12, 2012, and at times prior to, an exit way was half blocked with tires, exposing employees to fire hazards. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $1000
- — Z (S) $2800
1910.37 B02
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit." A) In the tire shop, on or about July 12, 2012, and at times prior to, "Exit" sign was missing on the door to the outside from the room, exposing employees to fire hazards. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C01
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $3,500 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) Sheet Metal Dept.- On or about and at times prior to July 12, 2012, employees service Big Press Brake, Stamco press, Bliss Mechanical press, Klinno Shear and Buffalo Iron worker. Employees did not have lockout/tagout training, did not use lockout/tagout and the employer did not have lockout/tagout procedures, exposing employees to electrical shock and amputation hazards. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED.
Recent events (2)
- — I (S) $1000
- — Z (S) $3500
1910.157 C01
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. A) In the workshop, on or about July 12, 2012, and at times prior to, fire extinguishers were blocked in the Jig 1 area, exposing employees to fire hazards.. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (O) $1000
- — Z (S) $2800
1910.212 A03 II
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $4,900 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. A) In the sheet metal shop, on or about July 12, 2012, and at times prior to, employees operated the Big Press Brake without a belt cover for the portion of the in-running nip point on the belt which was unguarded approximately 70 inches from the floor, exposing employees to amputation hazard. B) In the sheet metal shop, on or about July 12, 2012, and at times prior to, employees operated Stamco Press with a guard that had a gap which was 2 inches in size running along the length of the guard, exposing employees to amputation hazard. C) In the sheet metal shop, on or about July 12, 2012, and at times prior to, employees operated Bliss-21 with guard opening of approximately 3 inches, exposing employees to amputation hazard. D) In the sheet metal shop, on or about July 12, 2012, and at times prior to, employees operated Bufallo Iron worker with guard space which was in excess of 2 inches and allowed employees to place their fingers in the point of operation, exposing employees to amputation hazard. E) In the sheet metal shop, on or about July 12, 2012, and at times prior to, employees operated Bliss Mechanical Press with guard that allowed employees to place their fingers within 6 inches of the point of operation in two places, exposing employees to amputation hazard. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED.
Recent events (2)
- — I (O) $1250
- — Z (S) $4900
1910.217 B04 I
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $4,900 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.217(b)(4)(i): The pedal mechanism shall be protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedal. A) In the sheet metal shop, on or about July 12, 2012, and at times prior to, employee place metal to be worked within 3 inches from the point of operation of Press with no protection for press activation control pedal, exposing employees to amputation hazard. B) In the sheet metal shop, on or about July 12, 2012, and at times prior to, employee place metal to be worked within 3 inches from the point of operation of Bufallo-Iron worker with no protection for activation control pedal, exposing employees to amputation hazard. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED.
Recent events (2)
- — I (S) $1250
- — Z (S) $4900
1910.254 D08
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $3,500 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.254(d)(8): Electric shock. Cables with splices within 10 feet (3 m) of the holder shall not be used. The welder should not coil or loop welding electrode cable around parts of his body. A) In the jig 1 area, on or about July 12, 2012, and at times prior to, employees used welding electrode cables with splices within 7 feet from the rod holder, exposing employees to electric shock hazard. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED.
Recent events (2)
- — I (S) $1250
- — Z (S) $3500
1910.305 B03 II
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $4,900 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.305(b)(3)(ii): Boxes shall be closed by suitable covers securely fastened in place. Note to paragraph (b)(3)(ii) of this section: Underground box covers that weigh over 45.4 kg (100 lbs) meet this requirement. A) On or about July 12, 2012, and at times prior to, cover was missing from a 240 V electrical box 10 inches from the start/stop button of the Bliss Mechanical Press (19.5 Ton), exposing employees to electrical shock hazard. B) At jig 1, on or about July 12, 2012, and at times prior to, cover to 240 V disconnect box for Airco was left opened, exposing employees to electrical shock hazard. C) On or about July 12, 2012, and at times prior to, employees used 110 V outlet with no cover by Stamco press, exposing employees to electrical shock hazard. ABATEMENT CERTIFICATION AND DOCUMENTATIONS ARE REQUIRED.
Recent events (2)
- — I (S) $1250
- — Z (S) $4900
1910.305 G02 III
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. A) At jig 1 area, on or about July 12, 2012, and at times prior to, the control pendant electrical cord's outer insulation was pulled back and did not have any strain relief, the conductor was exposed and this condition exposed employees to an electrical shock hazard. B) At jig 1 area, on or about July 12, 2012, and at times prior to, on the electrical cord to control box # 6A, the cord's outer insulation was pulled back and did not have any strain relief, the conductor was exposed and this condition exposed employees to an electrical shock hazard. C) Big Press Brake, on or about July 12, 2012, and at times prior to, on the electrical cord to the on/off control, the cord's outer insulation was pulled back and did not havw any strain relief, the conductor was exposed and this condition exposed employees to an electrical shock hazard. ABATEMENT CERTIFICATI0N AND DOCUMENTATION ARE REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.179 L03
- Issued
- Jan 14, 2013
- Abate by
- Feb 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(l)(3): Adjustments and repairs. A) At jig 1 area, on or about July 12, 2012, and at times prior to, employees operated 2 ton overhead Jib Cranes with electric hoist to lift materials. The hook used with the hoist did not have a self closing spring operated latch across the throat of the hook to prevent material from accidentally becoming detached from the hook, exposing employees to struck-by falling material. ABATEMENT CERTIFICATION AND DOCUMENTATIONS ARE REQUIRED.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at FAB TEC, INC.
View FAB TEC, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335195996.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.