OSHA Inspection: STRIKE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STRIKE, LLC in 3.3 MILES SOUTH OF BP CHECK POINT, FREER, TX 78357 (NAICS 213112). OSHA activity number 335197174.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Strike, LLC for free Get an email when a new federal OSHA severe-injury report for Strike, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
STRIKE, LLC
Site address
3.3 MILES SOUTH OF BP CHECK POINT
City
FREER
State
TX
ZIP
78357
Mailing
1585 SAWDUST ROAD, SUITE 100, THE WOODLANDS, TX 77380
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
2
Ownership type
Private (A)

3 citations on file for this inspection.

1926.651 C02

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jul 25, 2012
Abate by
Jul 13, 2012
Penalty
Initial $3,400 · Current $0 Reduced
29 CFR 1926.651(c)(2):     A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.    At this trench site, employees were testing piping inside a trench that was approximately 6 feet deep.  The employees were not provided with a ladder or other safe means of egress.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3400

1926.651 K01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jul 25, 2012
Abate by
Jul 13, 2012
Penalty
Initial $4,250 · Current $0 Reduced
29 CFR 1926.651(k)(1):     Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:    At this trench site, employees were testing a gas pipeline in a trench approximately 6 feet deep.  No inspection was conducted by a competent person to avoid a situation that could result in a possible cave-in or other hazardous condition where there were indications of a potential cave-in.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4250

1926.652 A01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jul 25, 2012
Abate by
Jul 20, 2012
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1926.652(a)(1):     Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:    At this trench site, employees were testing a natural gas pipeline in a trench over 6 feet in depth.  The walls of the trench were not adequately sloped for the soil type; the employees were exposed to hazards associated with a cave-in.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4000

View Strike, LLC's full OSHA safety record →