OSHA Inspection: MALONE BOATBUILDING CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MALONE BOATBUILDING CO., INC. in 506 WEST STREET, ROCKPORT, ME 04856 (NAICS 336612). OSHA activity number 335198388.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Malone Boatbuilding CO., INC. for free Get an email when a new federal OSHA severe-injury report for Malone Boatbuilding CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
506 WEST STREET
City
ROCKPORT
State
ME
ZIP
04856
Mailing
506 WEST STREET, ROCKPORT, ME 04856
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
2
Ownership type
Private (A)

2 citations on file for this inspection.

1910.213 I01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2012
Abate by
Jul 28, 2012
Penalty
Initial $1,360 · Current $952 Reduced
29 CFR 1910.213(i)(1):     All portions of the saw blade shall be enclosed or guarded, except for the working portion of the blade between the bottom of the guide rolls and the table. Bandsaw wheels shall be fully encased. The outside periphery of the enclosure shall be solid. The front and back of the band wheels shall be either enclosed by solid material or by wire mesh or perforated metal. Such mesh or perforated metal shall be not less than 0.037 inch (U.S. Gage No. 20), and the openings shall be not greater than three-eighths inch. Solid material used for this purpose shall be of an equivalent strength and firmness. The guard for the portion of the blade between the sliding guide and the upper-saw-wheel guard shall protect the saw blade at the front and outer side. This portion of the guard shall be self-adjusting to raise and lower with the guide. The upper-wheel guard shall be made to conform to the travel of the saw on the wheel.      Wood Shop - The upper portion of the bandsaw did not have the 36 inch spoked wheel fully enclosed.
Recent events (2)
  • · I (S) $952
  • · Z (S) $1360

1910.242 B

Other-than-serious 1 instance 2 exposed
Issued
Jul 25, 2012
Abate by
Jul 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b):     Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.    Wood Shop - Compressed air used for cleaning parts and equipment was measured at 60 p.s.i.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Malone Boatbuilding CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335198388.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.