BELLE CHASSE, LA —
OSHA Inspection: STAINLESS FABRICATORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STAINLESS FABRICATORS, INC. in 9740 BELLE CHASSE HWY S (LA HWY 23), BELLE CHASSE, LA 70037 (NAICS 332313). OSHA activity number 335218384.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STAINLESS FABRICATORS, INC.
- Site address
- 9740 BELLE CHASSE HWY S (LA HWY 23)
- City
- BELLE CHASSE
- State
- LA
- ZIP
- 70037
- Mailing
- PO BOX 424, BELLE CHASSE, LA 70037
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 B01 IV
- Issued
- Jul 30, 2012
- Penalty
- Initial $867 · Current $520 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Safety of equipment was not determined using considerations for electrical insulation: a) The employer does not ensure that the safety of equipment is determined usign considerations for electrical insulation. This violation ocurred on or about July 12, 2012 when a flexible cord set was being used with damage in three places to the extermal insulation.
Recent events (2)
- — I (S) $520.2
- — Z (S) $867
1910.303 G02 I
- Issued
- Jul 30, 2012
- Abate by
- Aug 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) The employer does not ensure that live parts of electric equipment operating at 50 volts or more are guarded against accidental contact by use of approved cabinents or other forms of approved enclosures. This violation occurred on or about July 12, 2012 in the fabrication shop where a bench grinder (GE Model SP37NN322X) had a power switch box without an approved cover to guard against accidental contact with the electric equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Stainless Fabricators, INC.