Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IMCO INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of IMCO INC. in 15 TURNER DRIVE, SPENCERPORT, NY 14559 (NAICS 326199). OSHA activity number 335230983.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Imco INC. — free Get an email when a new federal OSHA severe-injury report for Imco INC. is published. One employer, no account, unsubscribe in one click.
Establishment
IMCO INC.
Site address
15 TURNER DRIVE
City
SPENCERPORT
State
NY
ZIP
14559
Mailing
15 TURNER DRIVE, SPENCERPORT, NY 14559
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
56
Ownership type
A

5 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 28, 2012
Abate by
Oct 22, 2012
Penalty
Initial $1,607 · Current $1,000 Reduced
29 CFR 1910.147(c)(7)(i)(A):  Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    a) Employees who service or performs maintenance, such as but not limited to saw blades and grinding wheel changes were not trained as authorized.    Abatement Certification Required:
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1607

1910.242 B

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 28, 2012
Abate by
Oct 22, 2012
Penalty
Initial $1,607 · Current $1,000 Reduced
29 CFR 1910.242(b):  Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.    a) On or about 7/19/12, employees were using compress air to clean metal shavings off molds that was over 30 p.s.i.    Abatement Certification Required:
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1607

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 28, 2012
Abate by
Oct 22, 2012
Penalty
Initial $1,607 · Current $1,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and cables were used as a substitute for the fixed wiring of a structure:    a) On or about 7/19/12, extension cords were used as permanent wire to power light on inspection table.    Abatement Certification Required:
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1607

1910.22 D01

Other-than-serious 1 instance 4 exposed
Issued
Sep 28, 2012
Abate by
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1):  In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent.    a) On or about 7/19/12, mezzanine use as storage did not a plate stating the load capacity for the area.    Abatement certification required:
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 II

Other-than-serious 1 instance 5 exposed
Issued
Sep 28, 2012
Abate by
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):  The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.    a) On or about 7/19/12, employer did not have documentation that the periodic inspection was performed last year.    Abatement certification Required:
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Imco INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335230983.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.