Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TIMBER RIDGE HOMES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TIMBER RIDGE HOMES in 5534 EXPRESSWAY DR. SOUTH, HOLTSVILLE, NY 11742 (NAICS 236115). OSHA activity number 335266987.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Timber Ridge Homes — free Get an email when a new federal OSHA severe-injury report for Timber Ridge Homes is published. One employer, no account, unsubscribe in one click.
Establishment
TIMBER RIDGE HOMES
Site address
5534 EXPRESSWAY DR. SOUTH
City
HOLTSVILLE
State
NY
ZIP
11742
Mailing
100 ADAMS AVE, HAUPPAUGE, NY 11788
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
20
Ownership type
A

7 citations on file for this inspection.

1926.451 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Sep 28, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.451(c)(2)(i):   Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement:      a)  Worksite, Exterior - Employee was installing siding and exterior window trim while working on a single scaffolding plank, approximately 12ft above the ground.  The plank was set up on the roof of the home; on or about 07/18/12.        Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.451 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7):   Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.      a)  Worksite, Exterior - Employee was installing siding and exterior window trim while working on a single scaffolding plank, approximately 12ft above the ground.  The plank was set up on the roof of the home; on or about 07/18/12.          Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1):   Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.      Worksite, Exterior - Employee was installing exterior window trim while working on a scaffolding plank approximately 12ft above the ground.  The employee was not protected from falling to the ground below; on or about 07/19/12.        Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Sep 28, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.501(b)(13):   Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.      a)  Worksite, Exterior - Employee was installing siding and window trim to the exterior of a two story residential unit.  The employee was walking on the roof and was exposed to a fall of approximately 12ft to the ground below; on or about 07/18/12.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.651 J02

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 27, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.651(j)(2):  Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.      a)  Worksite, South Side - The spoil pile was placed on the edge of the excavation; on or about 07/18/12.    b)  Worksite, East Side -   The spoil pile was placed on the edge of the excavation; on or about 07/18/12.        Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.651 K01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.651(k)(1):  Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions.      a)  Worksite, East Side - Employees were in an unprotected excavation without an inspection by a competent person; on or about 07/18/12.        Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.652 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.652(a)(1):   Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c) or 1926.652(b)(1)(i).     a) Worksite, Exterior - Employees were working in an excavation approximately 7ft deep.  The excavation had vertical walls and the employees were not protected from cave-ins by an adequate protective system; on or about 07/18/12.      Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

View Timber Ridge Homes's full OSHA safety record →