OSHA Inspection: CUSAY HOME IMPROVEMENTS

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CUSAY HOME IMPROVEMENTS in 5534 EXPRESSWAY DR. SOUTH, HOLTSVILLE, NY 11742 (NAICS 238170). OSHA activity number 335268983.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cusay Home Improvements — free Get an email when a new federal OSHA severe-injury report for Cusay Home Improvements is published. One employer, no account, unsubscribe in one click.
Site address
5534 EXPRESSWAY DR. SOUTH
City
HOLTSVILLE
State
NY
ZIP
11742
Mailing
507 MAURE AVE., EAST PATCHOGUE, NY 11772
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Sep 28, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(c)(2)(i):  Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement:      a)  Worksite, Exterior - Employee was installing siding and exterior window trim while working on a single scaffolding plank, approximately 12ft above the ground.  The plank was set up on the roof of the home; on or about 07/18/12.          Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7):   Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.      a)  Worksite, Exterior - Employee was installing siding and exterior window trim while working on a single scaffolding plank, approximately 12ft above the ground.  The plank was set up on the roof of the home; on or about 07/18/12.          Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1):   Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.      Worksite, Exterior - Employee was installing exterior window trim while working on a scaffolding plank approximately 12ft above the ground.  The employee was not protected from falling to the ground below; on or about 07/19/12.        Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2012
Abate by
Sep 28, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.501(b)(13):   Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.      a)  Worksite, Exterior - Employee was installing siding and window trim to the exterior of a two story residential unit.  The employee was walking on the roof and was exposed to a fall of approximately 12ft to the ground below; on or about 07/18/12.      Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View Cusay Home Improvements's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335268983.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.