Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J & J SHEET METAL WORKS

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of J & J SHEET METAL WORKS in 306 HIAWATHA BLVD WEST DESTINY USA, SYRACUSE, NY 13204 (NAICS 238220). OSHA activity number 335277984.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & J Sheet Metal Works — free Get an email when a new federal OSHA severe-injury report for J & J Sheet Metal Works is published. One employer, no account, unsubscribe in one click.
Site address
306 HIAWATHA BLVD WEST DESTINY USA
City
SYRACUSE
State
NY
ZIP
13204
Mailing
414 COMMERCE ROAD, VESTAL, NY 13850
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.56 A

Other-than-serious 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 17, 2012
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1926.56(a): While work was in progress, construction areas, ramps, runways, corridors, offices, shops or storage areas were not lighted to the minimum illumination intensities as listed in Table D-3 of 29 CFR 1926.56:    a) On or about 7/17/12, "ExcessR" store:  Employees performing work were not provided with at least 5 Lumens of light.    Abatement certification is required for this item.
Recent events (3)
  • — J (O) $1200
  • — C (S) $1200
  • — Z (S) $1200

1926.100 A

Other-than-serious 1 instance 1 exposed
Issued
Oct 2, 2012
Abate by
Oct 17, 2012
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    a) On or about 7/17/12, "ExcessR" store:  An employee performing work on the floor level was not wearing head protection.    Abatement certification is required for this item.
Recent events (3)
  • — J (O) $1000
  • — C (S) $1200
  • — Z (S) $1200

1926.153 J

Other-than-serious 1 instance 5 exposed
Issued
Oct 2, 2012
Abate by
Oct 17, 2012
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1926.153(j): Container(s) of liquefied petroleum gas (LP-Gas) were stored within building(s)    a) On or about 7/11/12, First Floor Storage/ "Office" area:  One LP gas cylinder for fork truck use was kept in storage.    Abatement certification is required for this item.
Recent events (3)
  • — J (O) $1000
  • — C (S) $1200
  • — Z (S) $1200

1926.404 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 17, 2012
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.    a) On or about 7/17/12, "ExcessR" store:  Employees were not protected by the use of a ground fault circuit interrupter while using temporary power.    Abatement certification is required for this item.
Recent events (3)
  • — J (O) $1000
  • — C (S) $1200
  • — Z (S) $1200

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) On or about 7/17/12, "ExcessR" store:  No path to ground was provided for a metal cased light.    Abatement certification is required for this item.
Recent events (3)
  • — J (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 F03

Other-than-serious 1 instance 2 exposed
Issued
Oct 2, 2012
Abate by
Oct 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a) On or about 7/11/12, "Off Broadway" store:  Employees were utilizing a scissor lift with a damaged control box.    Abatement certification is required for this item.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335277984.