FLUSHING, NY ·
OSHA Inspection: OSCAR A MENENDEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OSCAR A MENENDEZ in 75-75 182ND STREET, FLUSHING, NY 11366 (NAICS 238140). OSHA activity number 335279188.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OSCAR A MENENDEZ
- Site address
- 75-75 182ND STREET
- City
- FLUSHING
- State
- NY
- ZIP
- 11366
- Mailing
- 26 OAK AVE, HEMPSTEAD, NY 11550
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Aug 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked: A. On or about 07/10/12, scaffolds at 75-75 182nd Street. Flushing, NY Employees working on south side of the fabricated frame scaffolds were exposed to the hazard of falling approximately 13 ft. to the ground. The working platforms were installed with only two scaffold planks. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (1)
- · Z (O) $0
1926.451 E01
- Issued
- Aug 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: A). On or about 07/10/12, at 75-75 182nd Street. Flushing, NY Employees were ascending/descending scaffolds by climbing the frame and were in danger of falling approximately 13 ft. to the ground. An access ladder or equivalent safe devices were not provided. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (1)
- · Z (O) $0
1926.451 G01 VII
- Issued
- Aug 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on scaffolds, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: A). On or about 07/10/12, scaffolds at 75-75 182nd Street. Flushing, NY Employees applying stucco around the windows/house on the scaffold south side of the house were exposed to the hazard of falling approximately 13 ft. to the ground, respectively. Guardrails or personal fall arrest systems were not provided. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335279188.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.