OSHA Inspection: A. POMPO ELECTRIC INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of A. POMPO ELECTRIC INC. in 306 HIAWATHA BLVD WEST DESTINY USA, SYRACUSE, NY 13204 (NAICS 238210). OSHA activity number 335284204.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A. Pompo Electric INC. — free Get an email when a new federal OSHA severe-injury report for A. Pompo Electric INC. is published. One employer, no account, unsubscribe in one click.
Site address
306 HIAWATHA BLVD WEST DESTINY USA
City
SYRACUSE
State
NY
ZIP
13204
Mailing
1701 LEMOYNE AVE, SYRACUSE, NY 13208
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
14
Ownership type
A

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 3 instances 4 exposed
Issued
Oct 25, 2012
Abate by
Nov 8, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) On or about 7/11/2012, Guess Store:  Card board was used to cover two energized circuit breaker boxes.    b) On or about 7/11/2012, Janie and Jack Store:  A relocatable power tap was in use to energize equipment.    Abatement certification is required for this item.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1926.404 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Oct 25, 2012
Abate by
Nov 8, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.404(b)(1)(ii):  On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.    a) On or about 7/11/2012, Janie + Jack Store:  A Milwaukee saw was in use powered through extension cords, no GFCI or assured equipment grounding program was in use.    Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1926.451 B02

Other-than-serious 1 instance 1 exposed
Issued
Oct 25, 2012
Abate by
Nov 8, 2012
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.451(b)(2):  Scaffold platforms and walkways were not at least 18 inches wide:    a) On or about 7/11/2012, Hart Strings Store:  An employee was standing on the midrail which was being used as a platform that was not at least 18 inches wide.       Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1926.451 G04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 25, 2012
Abate by
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.    a) On or about 7/11/2012, Hart Strings Store:  No midrail was in place at the end of a scissor lift that an employee was working from.       Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View A. Pompo Electric INC.'s full OSHA safety record →