SYRACUSE, NY —
OSHA Inspection: A. POMPO ELECTRIC INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of A. POMPO ELECTRIC INC. in 306 HIAWATHA BLVD WEST DESTINY USA, SYRACUSE, NY 13204 (NAICS 238210). OSHA activity number 335284204.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A. POMPO ELECTRIC INC.
- Site address
- 306 HIAWATHA BLVD WEST DESTINY USA
- City
- SYRACUSE
- State
- NY
- ZIP
- 13204
- Mailing
- 1701 LEMOYNE AVE, SYRACUSE, NY 13208
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 14
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.403 B02
- Issued
- Oct 25, 2012
- Abate by
- Nov 8, 2012
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about 7/11/2012, Guess Store: Card board was used to cover two energized circuit breaker boxes. b) On or about 7/11/2012, Janie and Jack Store: A relocatable power tap was in use to energize equipment. Abatement certification is required for this item.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1926.404 B01 II
- Issued
- Oct 25, 2012
- Abate by
- Nov 8, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a) On or about 7/11/2012, Janie + Jack Store: A Milwaukee saw was in use powered through extension cords, no GFCI or assured equipment grounding program was in use. Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1926.451 B02
- Issued
- Oct 25, 2012
- Abate by
- Nov 8, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) On or about 7/11/2012, Hart Strings Store: An employee was standing on the midrail which was being used as a platform that was not at least 18 inches wide. Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1926.451 G04 I
- Issued
- Oct 25, 2012
- Abate by
- Nov 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. a) On or about 7/11/2012, Hart Strings Store: No midrail was in place at the end of a scissor lift that an employee was working from. Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at A. Pompo Electric INC.
View A. Pompo Electric INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335284204.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.