Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WINDOW SPECIALIST INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WINDOW SPECIALIST INC. in WEST SENECA WEST HIGH SCHOOL 3330 SENECA STREET, WEST SENECA, NY 14224 (NAICS 238150). OSHA activity number 335313797.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Window Specialist INC. — free Get an email when a new federal OSHA severe-injury report for Window Specialist INC. is published. One employer, no account, unsubscribe in one click.
Site address
WEST SENECA WEST HIGH SCHOOL 3330 SENECA STREET
City
WEST SENECA
State
NY
ZIP
14224
Mailing
188 ERIE STREET, LANCASTER, NY 14086
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238150
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.451 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 26, 2012
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)      a) On or about 7/19/12, at the West Seneca Senior High School Construction Site, 3330 Seneca St.,West Seneca, NY: Two employees were removing/installing Anodized Aluminum panels on the outside of the building while working from the top level of a mobile fabricated frame scaffold. The employees were exposed to a fall of 7 ft. because the level was not fully planked. The width of the scaffold between the uprights was 58 inches, and there were only two 18 3/4 inch wide "piks" in place instead of the three required.      NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1926.451 E08

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 26, 2012
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1926.451(e)(8):     Direct access to or from another surface was used when the scaffold was more than 14 inches (36 cm) horizontally and/or 24 inches (61 cm) vertically from the other surface:      a) On or about 7/19/12, at the West Seneca Senior High School Construction Site, 3330 Seneca St.,West Seneca, NY: Employees climbed the prefabricated end frame of the scaffold for access to the top work level. The scaffold wheels were on the concrete sidewalk and the vertical distance between the concrete surface and the bottom rung of the scaffold frame was 37 inches. No ladder was provided to bridge that gap.      NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1926.453 B02 V

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 26, 2012
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1926.453(b)(2)(v):     A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:  Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated      a) On or about 7/19/12, at the West Seneca Senior High School Construction Site, 3330 Seneca St., West Seneca, NY: An employee was exposed to potential fall of approx. 10 ft. while in the elevated "basket" of a "Terex" aerial lift taking measurements. The employee was not wearing a body belt/body harness with a lanyard, and was not tethered to the basket in any other way.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

View Window Specialist INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335313797.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.