ATHENS, PA —
OSHA Inspection: CAMCO MANUFACTURING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CAMCO MANUFACTURING, INC. in 101 N MAIN ST STE #2, ATHENS, PA 18810 (NAICS 332710). OSHA activity number 335314597.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAMCO MANUFACTURING, INC.
- Site address
- 101 N MAIN ST STE #2
- City
- ATHENS
- State
- PA
- ZIP
- 18810
- Mailing
- 101 N MAIN ST STE #2, ATHENS, PA 18810
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 100
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- Oct 4, 2012
- Penalty
- Initial $3,500 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Production Area: The employer did not establish an energy control program to protect maintenance workers exposed to electrical and mechanical hazards while performing servicing and maintenance on CNC machines, on or about July 20, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $3500
1910.212 A01
- Issued
- Oct 4, 2012
- Abate by
- Oct 12, 2012
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by the point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Production Area: A worker who operates a drill press with an unguarded chuck was exposed to an entaglement hazard, on or about July 20, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1910.242 B
- Issued
- Oct 4, 2012
- Abate by
- Oct 12, 2012
- Penalty
- Initial $2,100 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Production area: Compressed air used for cleaning by the drill press operator was not reduced to less than 30 psi, on or about July 20, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $2100
1910.303 B02
- Issued
- Oct 4, 2012
- Penalty
- Initial $3,500 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Production area: A relocateable power tap (power strip) on the test bench that was used to power a small refrigerator, a fan, a radio and a lamp was not installed and used in accordance with its intended purpose exposing workers to an electric shock hazard, on or about July 20, 2012. ABATEMENT OBSERVED DURING INSPECTION NO CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $3500
1910.305 G01 IV A
- Issued
- Oct 4, 2012
- Abate by
- Oct 12, 2012
- Penalty
- Initial $3,500 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Production area: An extension cord had been installed in placed of permanent wiring to provide electrical power to the oil skimmer on the Mori Seiki SV 500 vertical CNC machine exposing workers to an electric shock hazard, on or about July 20, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $3500
More inspections at Camco Manufacturing, INC.
View Camco Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335314597.