SYRACUSE, NY —
OSHA Inspection: RIMROCK DESIGN
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of RIMROCK DESIGN in 306 HIAWATHA BLVD WEST, SYRACUSE, NY 13204 (NAICS 238330). OSHA activity number 335316386.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIMROCK DESIGN
- Site address
- 306 HIAWATHA BLVD WEST
- City
- SYRACUSE
- State
- NY
- ZIP
- 13204
- Mailing
- 343 NW COLE TERRACE, LAKE CITY, FL 32055
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238330
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.303 B01
- Issued
- Oct 19, 2012
- Abate by
- Nov 2, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of American National Standards Institute, B7.1-1970, Safety Code for the Use, Care and Protection of Abrasive Wheels, and paragraph (d) of this section: a) On or about 7/17/2012, Second Floor Common Area: A Makita Angle Grinder was in use without a guard in place. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.404 B01 II
- Issued
- Oct 19, 2012
- Abate by
- Nov 2, 2012
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a) On or about 7/17/2012, Second Floor Common Area, two locations: Two Makita angle grinders, a Rigid drill, a DeWalt drill, and a Husqvarna saw were in use, powered through extension cords, no GFCIs or assured equipment grounding program was in use. Abatement certification is required for this item.