NORFOLK, VA ·
OSHA Inspection: SEAWARD MARINE SERVICES INC.
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of SEAWARD MARINE SERVICES INC. in USS WASP, PIER 10 NORFOLK NAVAL BASE, NORFOLK, VA 23513 (NAICS 336611). OSHA activity number 335316790.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEAWARD MARINE SERVICES INC.
- Site address
- USS WASP, PIER 10 NORFOLK NAVAL BASE
- City
- NORFOLK
- State
- VA
- ZIP
- 23513
- Mailing
- 5409 BEAMON ROAD, NORFOLK, VA 23513
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 130
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.305 B01 II
- Issued
- Sep 28, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $3,060 · Current $3,060
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a.) Seaward Marine Services, Inc., Shop Area, tool air/paint gear work bench. On or about July 16, 2012, the energized 120 volt single receptacle/light switch combination was not effectively closed in that a knockout plug was missing from the junction box exposing employees to live electrical parts.
Recent events (2)
- · I (O) $3060
- · Z (S) $3060
1910.305 G01 IV A
- Issued
- Sep 28, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a.) Seaward Marine Services, Inc., Shop Area, Break Room. On or about July 16, 2012 a Husky temporary flexible cord, 14 gauge, 125 volt, 15 amp, equipped with a three-way female attachment plug was being used in lieu of permanent wiring in that several appliances, a Toastmaster 2-slice toaster, Model T2020TW, 120volt, 850watt, a Infra-Chef sandwich oven, Model 1000, Serial No. 39771, and a Magic Chef Microwave, Model 100, 950 watt, were plugged into the cord and used by shop employees on a daily basis.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Seaward Marine Services INC.
View Seaward Marine Services INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335316790.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.