Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: DELRAY MOTORS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DELRAY MOTORS, INC. in 2102 SOUTH FEDERAL HIGHWAY, DELRAY BEACH, FL 33483 (NAICS 441110). OSHA activity number 335333589.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Delray Motors, INC. for free Get an email when a new federal OSHA severe-injury report for Delray Motors, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DELRAY MOTORS, INC.
Site address
2102 SOUTH FEDERAL HIGHWAY
City
DELRAY BEACH
State
FL
ZIP
33483
Mailing
2102 SOUTH FEDERAL HIGHWAY, DELRAY BEACH, FL 33483
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
210
Ownership type
Private (A)

5 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 29, 2012
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.    On or about 7/13/2012 , employees were exposed to a fire and health hazards as a result of poor housekeeping from the presence of accumulated combustible materials and debris such as but not limited to: empty corrugated boxes, waste paper, plastic bags, beverage containers and auto parts at a facility site located at 2102 South Federal Highway, Delray Beach, FL. 33483.
Recent events (2)
  • · I (S) $2295
  • · Z (S) $3825

1910.141 A04 II

Serious Gravity 1 10 exposed
Issued
Oct 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(4)(ii):     All sweepings, solid or liquid wastes, refuse, and garbage shall be removed in such a manner as to avoid creating a menace to health and as often as necessary or appropriate to maintain the place of employment in a sanitary condition.    On or about 7/13/2012, employees were exposed to health hazards from the presence accumulated refuse and garbage in containers that remained inside the facility overnight that attracted rodents at a facility located at 2102 South Federal Highway, Delray Beach, FL. 33483.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.141 A05

Serious Gravity 1 1 instance 10 exposed
Issued
Oct 29, 2012
Penalty
Initial $1,951 · Current $1,171 Reduced
29 CFR 1910.141(a)(5):     Vermin control. Every enclosed workplace shall be so constructed, equipped, and maintained, so far as reasonably practicable, as to prevent the entrance or harborage of rodents, insects, and other vermin. A continuing and effective extermination program shall be instituted where their presence is detected.    On or about 7/13/2012 , employees were exposed to health hazards from the presence of rodents and rodent droppings on floors and shelves at a facility that lacked an effective extermination program and permitted the entrance of rodents at a facility located at 2102 South Federal Highway, Delray Beach, FL. 33483.
Recent events (2)
  • · I (S) $1170.6
  • · Z (S) $1951

1910.305 B02 I

Serious Gravity 5 3 instances 10 exposed
Issued
Oct 29, 2012
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    On or about 7/13/2012 , employees were exposed to an electrical shock hazard while working in proximity to energized 110 VAC receptacle outlets and junction boxes that were not provided with  covers at a facility located at 2102 South Federal Highway, Delray Beach, FL. 33483.       Three Instances:  (a) Single receptacle in the Technicians locker room.  (b) Junction box in the Technicians locker room.  (c) Duplex receptacle in the parts counter area.
Recent events (2)
  • · I (S) $2295
  • · Z (S) $3825

1910.1200 H03

Other-than-serious 1 instance 3 exposed
Issued
Oct 29, 2012
Penalty
Initial $765 · Current $459 Reduced
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of sections (h)(3)(i)-(iv) of this paragraph:    On or about 7/13/2012, the employer did not provide employees with information and training at the time of their initial assignment on the potential health hazards of inorganic lead contained in key blanks and wheel weights for employees who were cutting keys and balancing wheels at a facility located at 2102 South Federal Highway, Delray Beach, FL. 33483.
Recent events (2)
  • · I (O) $459
  • · Z (O) $765

View Delray Motors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335333589.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.