Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: MANGAN CONSTRUCTION AND DEVELOPMENT, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MANGAN CONSTRUCTION AND DEVELOPMENT, INC. in 2121 W. SUNNYSIDE, CHICAGO, IL 60625 (NAICS 238160). OSHA activity number 335351789.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mangan Construction and Development, INC. for free Get an email when a new federal OSHA severe-injury report for Mangan Construction and Development, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2121 W. SUNNYSIDE
City
CHICAGO
State
IL
ZIP
60625
Mailing
601 S. PROSPECT AVENUE, PARK RIDGE, IL 60068
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
Private (A)

5 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 3, 2012
Abate by
Aug 6, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    a)  Employees were not provided with safe access to a ladder jack scaffold platform being used at an elevation of approximately 16 feet above the ground.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.451 G01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 3, 2012
Abate by
Aug 6, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    a) Employees were exposed to the hazard of falling while working from ladder jack scaffold platform elevated approximately 16 feet above the ground.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 3, 2012
Abate by
Aug 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a)  Employees engaged in roofing activity were not protected from fall hazards while working at an elevation of approximately 18 feet above the ground.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 3, 2012
Abate by
Sep 17, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.454(a):  The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    a)  Employees were not trained to recognize and eliminate the hazards associated with working from scaffolding.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 3, 2012
Abate by
Sep 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee who might be exposed to fall hazards:    a)  Employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Mangan Construction and Development, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335351789.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.