PROVIDENCE, RI ·
OSHA Inspection: THE AUDETTE GROUP LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE AUDETTE GROUP LLC in TWO REGENCY PLAZA, PROVIDENCE, RI 02903 (NAICS 238120). OSHA activity number 335362620.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE AUDETTE GROUP LLC
- Site address
- TWO REGENCY PLAZA
- City
- PROVIDENCE
- State
- RI
- ZIP
- 02903
- Mailing
- 4 FOX PLACE, PROVIDENCE, RI 02903
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 15
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.502 B01
- Issued
- Dec 27, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $2,800 · Current $2,400 Reduced
General-duty citation text
29 CFR 1926.502(b)(1): Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph. Jobsite, Two Regency Plaza, Providence, RI, Rooftop: On or about 07/19/2012, employees were engaged in construction activities on a low-sloped roof of a structure greater than 6 feet in height from the lower level and were not protected by from falls in that the warning line system in use as fall protection did not enclose the walking/working areas and a safety monitor was not being used exposing the employees to a fall of approximately 150 feet. ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- · I (S) $2400
- · Z (S) $2800
1926.760 B03
- Issued
- Dec 27, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.760(b)(3): Each connector working at heights over 15 and up to 30 feet above a lower level, was not provided with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off; or was not provided with other means of protection from fall hazards in accordance with paragraph (a)(1) of this section. Jobsite, Rooftop: On 07/19/2012 employees were engaged in steel erection activities on the Mechanical Penthouse structure greater than 6 feet in height from the lower level and were not protected by a guardrail system, net system, or personal fall protection exposing the employees to a fall of approximately 18 feet.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at The Audette Group LLC
View The Audette Group LLC's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335362620.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.