BROOKLYN, NY —
OSHA Inspection: J.A. LEE ELECTRIC INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of J.A. LEE ELECTRIC INC in 620 ATLANTIC AVE, BROOKLYN, NY 11217 (NAICS 238210). OSHA activity number 335365383.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.A. LEE ELECTRIC INC
- Site address
- 620 ATLANTIC AVE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11217
- Mailing
- 23-30 BORDEN AVE, LONG ISLAND CITY, NY 11101
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.404 F06
- Issued
- Sep 5, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a) Quad A Main Concourse: On or about July 24, 2012 An employee used a bandsaw which was plugged in by extension cord. The saw cord was missing the ground pin.
Recent events (1)
- — Z (S) $1600
1926.451 G01 VII
- Issued
- Sep 5, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Quad A Main Concourse: On or about July 24, 2012 An electrician was standing on the midrail of a scissors lift exposed to a greater than 10 fall while prepping a pipe run which was going to a closet for installation of DAS (Distributed Antennae System).
Recent events (1)
- — Z (S) $2000
1926.451 G04 I
- Issued
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. a) Quad A Main Concourse: On or about July 24, 2012 An employee used a scissors life with the midrail chain unfastened.
Recent events (1)
- — Z (S) $0