OSHA Inspection: PARK GROUP CONSTRUCTION, L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PARK GROUP CONSTRUCTION, L.L.C. in 518 S. PIERCE, LAFAYETTE, LA 70501 (NAICS 236116). OSHA activity number 335398186.

Watch Park Group Construction, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Park Group Construction, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
518 S. PIERCE
City
LAFAYETTE
State
LA
ZIP
70501
Mailing
326 SETTLERS TRACE BLVD SUITE 100B, LAFAYETTE, LA 70508
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.405 G01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.405(g)(1)(i): Flexible cords and cables were not suitable for conditions of use and location:    On or about July 17, 2012, the employer failed to ensure that flexible cords were suitable for use in wet locations. A flexible cord ran through water and was used as a power source for a DeWalt circular saw. Employees were using the circular saw to cut angle iron.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.405 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.405(g)(2)(iii): Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.    On or about July 17, 2012, the employer failed to ensure that flexible cords were continuous in length without splicing. Employees were using a spliced flexible cord as a power source for a DeWalt circular saw.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.405 G02 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    On or about July 17, 2012, the employer failed to ensure that flexible cords had adequate strain relief. The flexible cord was used by employee(s) as a power source for a DeWalt circular saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

OXYCHEM