ONEONTA, NY —
OSHA Inspection: TIOGA BUILDING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TIOGA BUILDING COMPANY in LUTZ FEED, LOWER RIVER STREET, ONEONTA, NY 13820 (NAICS 238120). OSHA activity number 335398988.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIOGA BUILDING COMPANY
- Site address
- LUTZ FEED, LOWER RIVER STREET
- City
- ONEONTA
- State
- NY
- ZIP
- 13820
- Mailing
- 333 GROS BOULEVARD, HERKIMER, NY 13350
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.453 B02 IV
- Issued
- Sep 19, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: a) North side of building, center, on or about 7-20-12: One employee was working in an articulating extensible boom aerial lift, while standing on the mid rails, exposing the employee to a fall hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $1200
1926.760 A01
- Issued
- Sep 19, 2012
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.: a) Center of building, on or about 7-20-12: Two employees were bolting and welding steel roof members without fall protection, exposing the employees to a fall hazard of 26 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.404 B01 II
- Issued
- Sep 19, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) Southwest corner of worksite, on or about 7-20-12: One employee was operating a hand held circular saw, powered through a duplex receptacle and extension cord that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (2)
- — I (O) $0
- — Z (S) $1200
More inspections in this industry (NAICS 238120)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335398988.