Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A2Z CONSTRUCTION GROUP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A2Z CONSTRUCTION GROUP, INC. in 2138 PROSPECT AVE, BRONX, NY 10457 (NAICS 238130). OSHA activity number 335402384.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A2Z Construction Group, INC. — free Get an email when a new federal OSHA severe-injury report for A2Z Construction Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2138 PROSPECT AVE
City
BRONX
State
NY
ZIP
10457
Mailing
1933 HONE AVE, BRONX, NY 10457
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.21 B02

Serious Gravity 1 5 instances 5 exposed
Issued
Sep 24, 2012
Penalty
Initial $1,320 · Current $660 Reduced
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:    On or about 7/25/2012, Job Site    a) The employees were not provided safety and health training as required by the standard.
Recent events (2)
  • — I (S) $660
  • — Z (S) $1320

1926.405 A02 II J

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 24, 2012
Penalty
Initial $1,320 · Current $660 Reduced
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designed for hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard or extra-hard usage:    NOTE: The National Electrical Code, ANSI/NFPA 70, in Article 400, Table 400-4, lists various types of flexible cords, some of which are noted as being designed for hard or extra-hard usage. Examples of these types of flexible cords include hard service cord (types S, ST, SO, STO) and junior hard service cord (types SJ, SJO, SJT, SJTO).    On or about 7/25/2012, Job Site    a) The employees were using a power strip to energize their tools.
Recent events (2)
  • — I (S) $660
  • — Z (S) $1320

1926.416 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 24, 2012
Penalty
Initial $1,320 · Current $660 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used:    On or about 7/25/2012, Job Site    a) The extension cord was frayed and had exposed wires.
Recent events (2)
  • — I (S) $660
  • — Z (S) $1320

1926.1051 A

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 24, 2012
Penalty
Initial $1,320 · Current $660 Reduced
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided:    On or about 7/25/2012, Job Site    a) A stairway or ladder was not provided at the front entrance.
Recent events (2)
  • — I (S) $660
  • — Z (S) $1320

1926.1053 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 24, 2012
Penalty
Initial $1,320 · Current $660 Reduced
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed:    On or about 7/25/2012, 3rd Floor    a) The employee used the a-frame ladder in the closed position.
Recent events (2)
  • — I (S) $660
  • — Z (S) $1320

1926.501 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 24, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    On or about 7/25/2012, 3rd Floor    a) The employees worked at the unprotected edge, installing wood beams.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.404 F06

Repeat Gravity 1 1 instance 1 exposed
Issued
Sep 24, 2012
Penalty
Initial $2,640 · Current $1,312 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous:      On or about 7/25/2012, Job Site    a) The extension cord used to energize the tools had the ground pin broken off.        NOTE: THE A2Z CONSTRUCTION GROUP, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS STANDARD OR ITS EQUIVALENT STANDARD 29CFR 1926.404(f)6, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 311279731 CITATION 1, ITEM 4b, ISSUED ON 11/15/2007    FOD:12/07/2007
Recent events (2)
  • — I (R) $1312
  • — Z (R) $2640

View A2Z Construction Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335402384.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.