Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: LIBERTY/ALPHA JV

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LIBERTY/ALPHA JV in 200 TERMINAL STREET, CHARLESTOWN, MA 02129 (NAICS 238990). OSHA activity number 335412581.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Liberty/Alpha JV for free Get an email when a new federal OSHA severe-injury report for Liberty/Alpha JV is published. One employer, no account, unsubscribe in one click.
Establishment
LIBERTY/ALPHA JV
Site address
200 TERMINAL STREET
City
CHARLESTOWN
State
MA
ZIP
02129
Mailing
200 TERMINAL STREET, CHARLESTOWN, MA 02129
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
50
Ownership type
A

2 citations on file for this inspection.

1926.152 D04

Other-than-serious 1 instance 5 exposed
Issued
Aug 16, 2012
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1926.152(d)(4):     At least one portable fire extinguisher having a rating of not less than 20B:C units was not provided on all vehicles used for transporting and/or dispensing flammable or combustible liquids      Jobsite:  Fuel Truck in the lay down area right out front of the office that is used primarly for "Dispensing Fuel" did not have any fire extinguisher in the immediate area.
Recent events (2)
  • · I (O) $2625
  • · Z (S) $3500

1926.405 G02 III

Other-than-serious 1 instance 3 exposed
Issued
Aug 16, 2012
Abate by
Aug 21, 2012
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.405(g)(2)(iii):     The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used:      Jobsite:  Employees had spliced power cord multiple times (3) three total when flexible cords sahll be used only in continuous lengths without a splice or tape.
Recent events (2)
  • · I (O) $2100
  • · Z (S) $2800

View Liberty/Alpha JV's full OSHA safety record →