CENTRE, AL ·
OSHA Inspection: BECHIK PRODUCTS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BECHIK PRODUCTS, INC. in 110 WARRIOR DR., CENTRE, AL 35960 (NAICS 314999). OSHA activity number 335421194.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BECHIK PRODUCTS, INC.
- Site address
- 110 WARRIOR DR.
- City
- CENTRE
- State
- AL
- ZIP
- 35960
- Mailing
- 110 WARRIOR DR., CENTRE, AL 35960
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314999
- Employees
- 21
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 B01
- Issued
- Sep 28, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. a) On or about July 25, 2012 - Finishing Range Area, a hose pipe was stretched across the aisle.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.24 E
- Issued
- Sep 28, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.24(e): Fixed stairs were not installed at angles to the horizontal of between 30 degrees and 50 degrees: a) On or about July 25, 2012 - Finishing Range Area, risers and treads were not erected within 30 to 50 degrees.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.147 C01
- Issued
- Sep 28, 2012
- Abate by
- Oct 15, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about July 25, 2012 - A program had not been established for employees that perform service, maintenance, or cleaning on equipment such as the Finishing Range.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.212 A01
- Issued
- Sep 28, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about July 25, 2012 - North Wall of shop, a finishing range had an unguarded rotating part.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.242 B
- Issued
- Sep 28, 2012
- Abate by
- Oct 1, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about July 25, 2012 - Spooling Department, compressed air was used with an output of 35 psi and greater while cleaning.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.304 F01 V
- Issued
- Sep 28, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(v): Fuses and circuit breakers for circuits rated 600 volts, nominal, or less were not located or shielded so that employees would not be burned or otherwise injured by their operation: a) On or about July 25, 2012 - Spooling Department, a fuse box was not shielded from employees.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.305 B02 I
- Issued
- Sep 28, 2012
- Abate by
- Oct 1, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy a) On or about July 25, 2012 - Spooling Department station #1, electrical switch cover missing exposing employee to live parts. b) On or about July 25, 2012 - Spooling Department station #1, electrical switch broken exposing employees to live parts. c) On or about July 25, 2012 - Spooling Department station #2, metal electric box missing cover with wires running through box, exposing employees to live parts. d) On or about July 25, 2012 - Spooling Department station #3, metal box used as a plug is missing a cover exposing employees to live parts. e) On or about July 25, 2012 - Spooling Department station #4, metal switch missing cover exposing employees to live parts.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.303 G01
- Issued
- Sep 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a)On or about 07/25/2012 - Finishing range area, boxes were stored in front of an electrical panel.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- Sep 28, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about July 25, 2012 - Plant, a hazardous communication program had not been established for employees that handle chemicals, such as Dyeresin 350-S and propylene glycol.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 F05 I
- Issued
- Sep 28, 2012
- Abate by
- Oct 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) On or about July 25, 2012 - At the Finishing Department, many plastic containers were not marked to identify the chemical within it.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Bechik Products, INC.
View Bechik Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 314999)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335421194.