STREAMWOOD, IL ·
OSHA Inspection: CARQUEVILLE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CARQUEVILLE in 1536 BROUBON PARKWAY, STREAMWOOD, IL 60107 (NAICS 323111). OSHA activity number 335423786.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARQUEVILLE
- Site address
- 1536 BROUBON PARKWAY
- City
- STREAMWOOD
- State
- IL
- ZIP
- 60107
- Mailing
- 1536 BROUBON PARKWAY, STREAMWOOD, IL 60107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 46
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.147 C06 I
- Issued
- Aug 7, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $4,250 · Current $2,125 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Facility Wide - An annual or more frequent inspection of the energy control procedure was not completed to ensure the procedure was being followed and requirements of the standard were followed for machinery including but not limiited to the printing press #57. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- · I (S) $2125
- · Z (S) $4250
1910.178 G02
- Issued
- Aug 7, 2012
- Abate by
- Oct 5, 2012
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks: a) Battery Charging Area/ Bindery - No protection was provided for six out of the seven industrial truck battery charging apparatuses. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- · I (S) $1275
- · Z (S) $2550
1910.178 L04 III
- Issued
- Aug 7, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $3,400 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Facility wide - All powered industrial truck operators were not evaluated on the operation of the powered industrial trucks at least once every three years. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- · I (S) $1700
- · Z (S) $3400
1910.212 A01
- Issued
- Aug 7, 2012
- Penalty
- Initial $2,890 · Current $1,445 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Printing Press Area/ Press 57 - The coater component of Press 57 was not guarded during operation. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (S) $1445
- · Z (S) $2890
1910.303 B02
- Issued
- Aug 7, 2012
- Penalty
- Initial $2,168 · Current $1,455 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Bindery Area/ Skid packing - A power stripwas used for woodworking hand power tools such as Skilsaw worm drive saw S/N - HG-00479. It was not used in accordance with instructions included in the listing or labeling. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (S) $1455
- · Z (S) $2168
1910.334 A02 I
- Issued
- Aug 7, 2012
- Penalty
- Initial $723 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) Skid builder area/ Bindery area - A skilsaw worm drive saw (SN - HG00479) had a damaged outer jacket or insulation at the connection point of the flexible cord and the beginning of the saw along with electrical tape being wrapped on the flexible cord itself about six inches below the handle. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $723
1910.305 B01 II
- Issued
- Aug 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Skid Turner Location/ Pressroom - The skid turners electrical panel was not effetively closed and secured. No abatement certification or documentation is required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 323111)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 335423786.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.