CLARKSBURG, WV —
OSHA Inspection: DUARTE'S ROOFING & SHEET METAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DUARTE'S ROOFING & SHEET METAL, INC. in 100 JONES STREET, CLARKSBURG, WV 26301 (NAICS 238160). OSHA activity number 335433785.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DUARTE'S ROOFING & SHEET METAL, INC.
- Site address
- 100 JONES STREET
- City
- CLARKSBURG
- State
- WV
- ZIP
- 26301
- Mailing
- 412 NORTH OHIO AVENUE, CLARKSBURG, WV 26301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.20 B01
- Issued
- Dec 5, 2012
- Abate by
- Dec 24, 2012
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as necessary to comply with this part: (a) The employer had not developed a safety program that would address the hazards observed on site at a roofing job located at 100 Jones Street in Clarksburg, WV such as, but not limited to, the use of a scaffold near an energized electric line as determined on July 25, 2012. ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.20 B02
- Issued
- Dec 5, 2012
- Abate by
- Jan 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) (a) A competent person was not present to conduct inspections of the worksite, located at 100 Jones Street in Clarksburg, WV, to identify safety and health hazards as supported by the hazardous conditions found including, but not limited to, the use of a ladder jack scaffold close to an energized power line as determined on July 25, 2012. ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F06
- Issued
- Dec 5, 2012
- Abate by
- Dec 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6): (a) An employees was working from a ladder jack scaffold erected at a house located at 100 Jones Street in Clarksburg, WV and the ladder jack scaffold was located within the three foot allowed distance of an insulated power line of 300 volts or less as observed on July 25, 2012. ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.21 B02
- Issued
- Dec 5, 2012
- Abate by
- Jan 11, 2013
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: (a) Employees working at a jobsite located at 100 Jones Street in Clarksburg, WV were not provided safety and health hazard training by their employer to aid in recognizing hazards such as, but not limited to, the use of a portable step ladder used to gain access to a scaffold and the ladder's top step was even with the scaffold platform, as determined on July 25, 2012. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.1053 B01
- Issued
- Dec 5, 2012
- Abate by
- Dec 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect and a grasping device was not provided to assist employees in mounting and dismounting the ladder: (a) At a job site located at 100 Jones Street in Clarksburg, WV, employees were exposed to a fall hazard in that a portable step ladder was used to gain access to a scaffold and the ladder's top step was even with the scaffold platform. The ladder was not secured from falling over and a grasping device was not in place to aid employees getting on and off of the ladder as determined on July 25, 2012. ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 I
- Issued
- Dec 5, 2012
- Abate by
- Dec 17, 2012
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: (a) An employee working on a ladder jack scaffold at a house located at 100 Jones Street in Clarksburg, WV was not protected from the thirteen and a half foot fall distance by a personal fall arrest system as observed on July 25, 2012. ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1926.501 B13
- Issued
- Dec 5, 2012
- Abate by
- Jan 11, 2013
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 100 Jones Street, Clarksburg WV. Employees were working on a 7 on 12 sloped roof, with a maximum fall hazard of 14 feet, and the employer had not implemented any fall protection measures as determined on July 25, 2012. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1926.102 A02
- Issued
- Dec 5, 2012
- Abate by
- Dec 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.102(a)(2): Eye and face protection required by this Part did not meet the requirements specified in American National Standards Institute, Z87.1-1968, Practice for Occupational and Educational Eye and Face Protection: (a) Employees that required corrective lenses were not wearing eye protection that had been designed to protect employees from impact hazards that can be encountered when working with or near equipment such as, but not limited to, nail guns as determined on July 25, 2012. ABATEMENT CERTIFICATION REQUIRED