OSHA Inspection: TOM GRISHABER BUILDERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TOM GRISHABER BUILDERS in ST ROAD 73, LOGAN, WV 25601 (NAICS 236220). OSHA activity number 335434585.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TOM Grishaber Builders for free Get an email when a new federal OSHA severe-injury report for TOM Grishaber Builders is published. One employer, no account, unsubscribe in one click.
Site address
ST ROAD 73
City
LOGAN
State
WV
ZIP
25601
Mailing
1223 PAULA ROAD, CHARLESTON, WV 25314
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 17, 2012
Abate by
Aug 24, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:     (a) Welcome Center work-site: An employee was working on a fabricated frame scaffold, three bucks high, installing insulation to the interior gable wall.  The scaffold legs did not bear on base plates, as observed on July 24, 2012.    (b) Welcome Center work-site: An employee was working on a fabricated frame scaffold, three bucks high, installing insulation to the interior side of the trusses.  The scaffold legs did not bear on base plates, as observed on July 24, 2012.    Abatement Certification Required for this item
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1926.451 F07

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 17, 2012
Abate by
Aug 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7):      Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employee under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:    (a)  Welcome Center work-site: Fabricated frame scaffolds were used to install insulation to the interior gable wall and trusses and were erected without base plates and did not have an adequate guardrail system installed.  The scaffold was not erected under the supervision and direction of a competent person qualified in scaffold erection to ensure base plates and guardrails were installed, as determined on July 24, 2012.    ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G01 VII

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 17, 2012
Abate by
Aug 24, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.451(g)(1)(vii):     Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    (a)  Welcome Center work-site: An employee was exposed to a fall while working on a scaffold at approximately 11 to 14 feet high that did not have a guardrail system installed.  The scaffold did not have a guardrail system that meet the requirements of paragraph (g)(4)of this section and a personal fall arrest system was not used, as determined on July 24, 2012.    (b)  Welcome Center work-site: An employee was exposed to a fall while working on a scaffold at approximately 12 1/2 to 14 feet high that did not have a guardrail system installed.  The scaffold did not have a guardrail system that meet the requirements of paragraph (g)(4)of this section and a personal fall arrest system was not used, as determined on July 24, 2012.    ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 17, 2012
Abate by
Aug 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a):    The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedure(s) to control or minimize those hazards:    (a)  Welcome Center work-site: Employees were exposed to fall hazards, and tipping hazards while working on a scaffold that did not have guardrails or base plates installed.  Employees were not trained to recognize and understand the procedures to control or minimize the tipping hazards and the potential for scaffold collapse, as determined on July 24, 2012.    ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.452 C02

Other-than-serious 1 instance 2 exposed
Issued
Aug 17, 2012
Abate by
Aug 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.452(c)(2):    Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:    (a) Welcome Center work-site:  An employee was working on a scaffold installing insulation to the interior side of the gable wall.  One side of a scaffold section did not have the cross bracing installed to secure all vertical members together, as observed on July 24, 2012.    (b) Welcome Center work-site:  An employee was working on a scaffold installing insulation to the interior side of the trusses.  One side of a scaffold section did not have the cross bracing installed to secure all vertical members together, as observed on July 24, 2012.    ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM