OSHA Inspection: TUCKER LUMBER COMPANY LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TUCKER LUMBER COMPANY LLC in 350 COLUMBIA 245, TAYLOR, AR 71861 (NAICS 321113). OSHA activity number 335441192.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tucker Lumber Company LLC — free Get an email when a new federal OSHA severe-injury report for Tucker Lumber Company LLC is published. One employer, no account, unsubscribe in one click.
Site address
350 COLUMBIA 245
City
TAYLOR
State
AR
ZIP
71861
Mailing
15061 HIGHWAY 371 SOUTH, TAYLOR, AR 71861
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
14
Ownership type
A

8 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 31, 2012
Abate by
Nov 7, 2012
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.    On or about July 26, 2012 and times prior thereto employees were exposed to tripping hazards from the accmulations of scrap and debris on the step leading to the operator's platform near the edging station.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.24 B

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 31, 2012
Abate by
Nov 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.24(b):     Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations:    On or about July 26, 2012 and times prior thereto, employees were exposed to trip/fall hazards accessing the work platform located near the edging station.  The platform is approximately 33 inches above the ground and loose lumber is being used in lieu of a fixed step.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 31, 2012
Abate by
Nov 23, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about July 26, 2012 and times prior thereto, employees were exposed to pinch points created by unguarded powered belts and pulleys in the following instanes:    instance a.) ground level on the chip shaker conveyor    instance b.) on the hydraulic unit for the mainsaw
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.219 F03

Serious Gravity 5 5 instances 14 exposed
Issued
Oct 31, 2012
Abate by
Nov 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3):     Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.    On or about July 26, 2012 and times prior thereto, employees were exposed to pinch points created by unguarded chains and sprockets that were located less than 7 feet above the floor in the following instances:    instance a.) back side of the main head conveyor  instance b.) back side of belt conveyor feeding shaker conveyor at ground level  instance c.) main head saw area drive mechanism for lug conveyor  instance d.) conveyor drive by edger  instance e.) on both sides at the end of the flat belt conveyor
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 2 instances 14 exposed
Issued
Oct 31, 2012
Abate by
Nov 7, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    On or about July 26, 2012 and times prior thereto, employees were exposed to shock and fire hazards created by missing covers on electrical boxes in the following instances:    instance a.) on the junction box for the main air compressor for the mill.  instance b.) on the hydraulic unit for the side transfer conveyor off of the head rig.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.305 G01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 31, 2012
Abate by
Nov 23, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about July 26, 2012 and times prior thereto, employees were exposed to fire and shock hazards by the flexible power cord run along the ground powering the main, permanently mounted air compressor for the mill.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 G01 IV B

Serious Gravity 5 1 instance 14 exposed
Issued
Oct 31, 2012
Abate by
Nov 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B):     Flexible cords and cables were run through holes in walls, ceilings, or floors    On or about July 26, 2012 and times prior thereto, employees were exposed to shock and fire hazards from a flexible electrical power cord for the hydraulic unit at the side transfer conveyor off of the head rig.  The flexible power cord was run through a hole in the wall at the electrical room and run along the corrugated metal building wall to the unit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 5 instances 14 exposed
Issued
Oct 31, 2012
Abate by
Nov 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6):     The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l)    On or about July 26, 2012 and times prior thereto, employer did not certify that all operators of powered industrial trucks had been trained in their safe operation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Tucker Lumber Company LLC's full OSHA safety record →