MERIDIAN, ID —
OSHA Inspection: TUFFY EXCAVATION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TUFFY EXCAVATION, INC. in 3475 N. EAGLE ROAD, MERIDIAN, ID 83646 (NAICS 238910). OSHA activity number 335448387.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TUFFY EXCAVATION, INC.
- Site address
- 3475 N. EAGLE ROAD
- City
- MERIDIAN
- State
- ID
- ZIP
- 83646
- Mailing
- 4028 BANNER, BOISE, ID 83709
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Northwest corner of site; On or about July 26, 2012 and at times prior thereto, an employee assisting with measuring the grade of a 4 foot deep excavation with nearly vertical walls for the installation of PVC waste water piping was not provided with a safe means of entering/exiting. The employee was observed jumping into and climbing up the excavated wall to get out of the excavation. Note: Abatement certification is NOT required for this item.
Recent events (1)
- — Z (O) $0
1926.651 J02
- Issued
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) Southeast corner to the northeast corner to the northwest corner of site; On or about July 26, 2012 and at times prior thereto, employees were setting PVC waste water piping in a 4 foot deep excavation with nearly vertical walls and the excavated material piled up at the immediate edge of the excavation. Note: Abatement certification is NOT required for this item.
Recent events (1)
- — Z (O) $0
More inspections at Tuffy Excavation, INC.