Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LONE STAR FRAMING SOLUTIONS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LONE STAR FRAMING SOLUTIONS in 2800 ST. FEDERICO WAY, ROUND ROCK, TX 78665 (NAICS 238130). OSHA activity number 335454385.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lone Star Framing Solutions — free Get an email when a new federal OSHA severe-injury report for Lone Star Framing Solutions is published. One employer, no account, unsubscribe in one click.
Site address
2800 ST. FEDERICO WAY
City
ROUND ROCK
State
TX
ZIP
78665
Mailing
40105 INDUSTRIAL PARK CIRCLE #102, GEORGETOWN, TX 78626
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.416 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 31, 2012
Abate by
Aug 14, 2012
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1926.416(e)(1):     Worn or frayed electric cords or cables were used:    On or about July 30, 2012, the cord to the Makita circular saw had a cut in the insulation, exposing employees to an electrical shock hazard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the cut in the circular saw cord is fixed.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.405 G02 IV

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 31, 2012
Abate by
Aug 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):     Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    On or about July 30, 2012, the cord to the Makita circular saw had exposed wires where the cord attaches to the plug, exposing employees to an electrical shock hazard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the strain relief issue on the circular saw cord are fixed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 31, 2012
Abate by
Aug 21, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.501(b)(13):     Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    On or about July 30, 2012, an employee was working on the top plate of a residential structure approximately nine feet and four inches high without fall protection, exposing the employee to a fall hazard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that fall protection is provided to and used by employees.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.503 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 31, 2012
Abate by
Aug 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1):     The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    On or about July 30, 2012, an employee was working on the top plate of a residential structure at approximately nine feet and four inches high without the employer providing fall protection training, exposing the employee to a fall hazard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that fall protection training is provided to the employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1051 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 31, 2012
Abate by
Aug 14, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1051(a):     Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided:    On or about July 30, 2012, and at times prior thereto, an employee used the building frame to access the top plate of a residential structure approximately nine (9) feet and four (4) inches high, exposing the employee to a fall hazard.      Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees use a ladder to access anywhere on site that has an elevation change greater than nineteen (19) inches.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.1060 A

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 31, 2012
Abate by
Aug 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a):     The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards.    On or about July 30, 2012, and at times prior thereto, employees were not trained how to properly use a ladder, exposing the employee to a fall hazard.      Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees use a ladder to access anywhere on site that has an elevation change greater than nineteen (19) inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Lone Star Framing Solutions's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335454385.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.