Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EXCEL MANUFACTURING

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of EXCEL MANUFACTURING in 3517 FRUTAS, EL PASO, TX 79905 (NAICS 315210). OSHA activity number 335454591.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Excel Manufacturing — free Get an email when a new federal OSHA severe-injury report for Excel Manufacturing is published. One employer, no account, unsubscribe in one click.
Establishment
EXCEL MANUFACTURING
Site address
3517 FRUTAS
City
EL PASO
State
TX
ZIP
79905
Mailing
3517 FRUTAS, EL PASO, TX 79905
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
315210
Employees
270
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 4, 2012
Abate by
Dec 31, 2012
Penalty
Initial $6,000 · Current $3,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    On July 18, 2012, and times prior to, in the Northwest part of the sewing room machine guarding was not present on a sewing machine.  This conditon exposed employees to rotating parts such as a belt and pulley.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $6000

1910.212 A05

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 4, 2012
Abate by
Dec 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch.    On July 18, 2012, and times prior to, employees were working near an evaporative cooler which did not have adequate machine guarding.  This condiiton exposed employees to lacerations and potential amputation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 5 1 instance 270 exposed
Issued
Dec 4, 2012
Abate by
Dec 31, 2012
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electrical equipment rated 600 volts, nominal, or less to ground, was in a passageway or general open space and was not suitably guarded when normally enclosed live parts were exposed for inspection or servicing.    On July 18, 2012, and times prior to, the electrical panel used to control the vacuums in the building was blocked.  In the event of an emergecy, employee would not have safe access to turn off power to the buidling.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4000

1910.305 A02 VIII

Serious Gravity 5 1 instance 270 exposed
Issued
Dec 4, 2012
Abate by
Dec 31, 2012
Penalty
Initial $5,000 · Current $2,600 Reduced
29 CFR 1910.305(a)(2)(viii): Disconnecting switches or plug connectors were not installed to permit the disconnection of all ungrounded conductors of each temporary circuit    b.) On July 18 2012, and times prior to, employees were using a fan for temperature control that had a jumper wire used to turn on/off the fan.  This condition exposed employee to electrical shocks and possible electrocution.
Recent events (2)
  • — I (S) $2600
  • — Z (S) $5000

1910.305 B02 I

Serious Gravity 5 2 instances 10 exposed
Issued
Dec 4, 2012
Abate by
Dec 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose.    On July 18 2012, employees were using a fan for tempurature control that was misisng a cover to the electrical box with exposed live electrical parts while energized.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 2 instances 5 exposed
Issued
Dec 4, 2012
Abate by
Dec 31, 2012
Penalty
Initial $5,000 · Current $2,000 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.    On July 18, 2012, and times prior to, 3 electrical panels along the South wall of the sewing room unused openings that were not effectively closed.  This conditon exposed employee to electrical shock and electrocution.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335454591.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.