Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: D.S.R. CONSTRUCTION SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of D.S.R. CONSTRUCTION SERVICES, INC. in 2885 MIDDLECREEK WAY, CUMMING, GA 30041 (NAICS 238130). OSHA activity number 335454799.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D.S.R. Construction Services, INC. for free Get an email when a new federal OSHA severe-injury report for D.S.R. Construction Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2885 MIDDLECREEK WAY
City
CUMMING
State
GA
ZIP
30041
Mailing
726 MUIRFIELD DR, WINDER, GA 30680
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
Private (A)

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 4 exposed
Issued
Aug 24, 2012
Abate by
Sep 17, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(13):  Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b)    On or about July 25, 2012:    Employees were exposed to fall hazards while engaged in residential construction activities of the following instances:    a) Employee was exposed to fall hazards of approximately 19.6 feet while walking on the top plate section of a newly erected wall, prepping area to recieve trusses.    b) Employees were exposed to fall hazards of approximately 10.6 feet while working around wall openings without the use of fall protection measures.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1926.503 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 24, 2012
Abate by
Sep 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1):     The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    On or about July 25, 2012:    Employer failed to implement and maintain a training program for the employees expopsed to fall hazards in the following instances.    a) Employee exposed to fall of approximately 19.6 feet while walking on top plate of second floor area.    b) Employees working exposed to fall hazards of approximately 10.6 feet while working around wall openings on second floor.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 24, 2012
Abate by
Sep 17, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1926.1053(b)(1):     Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    On or about July 25, 2012:    Employees were exposed to fall hazards of approximately 10.6 feet while trying to utilize a ladder to access the second floor working area, and ladder used did not have rails extended at least three feet above the upper landing surface.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 24, 2012
Abate by
Sep 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13):     The top or top step of a stepladder was used as a step:    On or about July 25, 2012:    Employee was exposed to fall hazard of approximately 10.6 feet while standing on the top step of a step ladder to reach the top plate area of the second floor exterior walls.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1060 A

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 24, 2012
Abate by
Sep 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a):     The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards.    On or about July 25, 2012;    Employer failed to implement and maintain a training program for employees using ladders in the following situation:    a) Employees exposed to falls of approximately 10.6 feet while using a ladder to access an upper landing where the rails of ladder did not extend at least three feet above landing area.    b) Employee exposed to fall hazard of approximately 10.6 feet while standing on the top step of a step ladder to reach top plate area of second floor exterior wall.