OSHA Inspection: ATW AUTOMATION, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of ATW AUTOMATION, INC. in 313 MOUND STREET, DAYTON, OH 45402 (NAICS 333298). OSHA activity number 335462792.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ATW Automation, INC. — free Get an email when a new federal OSHA severe-injury report for ATW Automation, INC. is published. One employer, no account, unsubscribe in one click.
Site address
313 MOUND STREET
City
DAYTON
State
OH
ZIP
45402
Mailing
313 MOUND STREET, DAYTON, OH 45402
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333298
Employees
142
Ownership type
A

9 citations on file for this inspection.

1910.133 A02

Serious Gravity 5 1 instance 15 exposed
Issued
Nov 20, 2012
Abate by
Dec 3, 2012
Penalty
Initial $4,000 · Current $4,000
29 CFR 1910.133(a)(2):     The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable.    On or about August 8, 2012, in the Commerical Machine Department, an machinist employee was exposed to flying metal chips due to the lack of side protection on his safety glasses while drilling holes in a metal plate on a De Vlieg milling machine.
Recent events (3)
  • — F (S) $4000
  • — C (S) $4000
  • — Z (S) $4000

1910.147 C04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Nov 20, 2012
Abate by
Dec 24, 2012
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(4)(i):     Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.    A specific energy control procedure for the Denso Machine, of which the Pole Core Station lift roller conveyor was a component, which included electrical and pneumatic energy sources, had not been developed nor implemented.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.147 C07 I A

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2012
Abate by
Jan 9, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.147(c)(7)(i)(A):     Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    The computer internet-based training which authorized employees received was inadequate in that the training did not address the specific energy control procedures from the machines and equipment in the facility and the methods and means necessary for energy isolation and control.
Recent events (3)
  • — F (S) $5000
  • — C (S) $5000
  • — Z (S) $5000

1910.147 D02

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 20, 2012
Abate by
Dec 10, 2012
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(d)(2):     Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.212 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Nov 20, 2012
Abate by
Jan 9, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.212(a)(1):     Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    On or about July 27, 2012, in the Custom Machine Build Department, on the Pole Core Station, a component of the Denso Machine, an employee (electrician) was exposed to a struck-by, caught inbetween hazard due to the lack of guarding around the Alba lift roller conveyor when the upper section of the conveyor moved downward during a powered down condition.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.215 D03

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 20, 2012
Penalty
Initial $3,000 · Current $3,000
29 CFR 1910.215(d)(3):     Surface condition. All contact surfaces of wheels, blotters and flanges shall be flat and free of foreign matter.    In the Fabrication Department in front of the Scotchman Chopsaw, an fabrication employee was exposed to a struck-by hazard from the grinding of nonferrous metal on the surface of a grinding wheel.
Recent events (3)
  • — F (S) $3000
  • — C (S) $3000
  • — Z (S) $3000

1910.332 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 20, 2012
Abate by
Apr 30, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.332(b)(1):     Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments.    An employee who performs energized electrical work in the form of troubleshooting on facility and machine electrical circuits of 480 Volts AC and below had not been trained to know when and what to wear to protect themselves against electric shock and arc flash.
Recent events (3)
  • — F (S) $5000
  • — C (S) $5000
  • — Z (S) $5000

1910.147 C06 I

Repeat Gravity 5 1 instance 5 exposed
Issued
Nov 20, 2012
Abate by
Jan 9, 2013
Penalty
Initial $25,000 · Current $5,000 Reduced
29 CFR 1910.147(c)(6)(i):     The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    Periodic inspections of the company's specific energy control procedures had not been conducted on at least an annual basis.
Recent events (3)
  • — F (R) $5000
  • — C (R) $25000
  • — Z (R) $25000

1910.137 B02 VIII

Other-than-serious 1 instance 1 exposed
Issued
Nov 20, 2012
Abate by
Jan 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.137(b)(2)(viii):     Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-5 and Table I-6.    Insulated rubber gloves used by an maintenance employee had not been tested every 6 months to ensure their serviceability for use.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335462792.