OSHA Inspection: ARGUS CONTRACTING LP

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ARGUS CONTRACTING LP in 1313 MOTOR CITY DRIVE, COLORADO SPRINGS, CO 80905 (NAICS 562910). OSHA activity number 335466389.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Argus Contracting LP — free Get an email when a new federal OSHA severe-injury report for Argus Contracting LP is published. One employer, no account, unsubscribe in one click.
Site address
1313 MOTOR CITY DRIVE
City
COLORADO SPRINGS
State
CO
ZIP
80905
Mailing
4181 W. I70 FRONTAGE ROAD, ARVADA, CO 80002
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.405 G02 IV

Deleted Serious Gravity 1 1 instance 10 exposed
Issued
Sep 28, 2012
Abate by
Oct 1, 2012
Penalty
Initial $1,080 · Current $0 Reduced
29 CFR 1926.405(g)(2)(iv):  Flexible cords were not connected to devices and fittings so that strain relief was provided which would prevent pull from being directly transmitted to joints or terminal screws:    a)  On or about July 20, 2012, employees were exposed to electrical shock because strain relief was not provided on an electrical cord used to power an air handling machine for asbestos abatement work.        Abatement Note:  Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $1080

1926.1101 H03 IV A

Other-than-serious 1 instance 3 exposed
Issued
Sep 28, 2012
Abate by
Oct 31, 2012
Penalty
Initial $1,800 · Current $1,800
29 CFR 1926.1101(h)(3)(iv)(A):  A tight-fitting powered air-purifying respirator or a full facepiece, supplied-air respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure, self-contained breathing apparatus (SCBA) was not provided to employees in a regulated area performing Class I asbestos work for which a negative exposure assessment was not available and the exposure assessment indicated that the exposure level will be at or below 1 f/cc as an 8-hour time-weighted average (TWA):    a)  On or about July 20, 2012, and at times prior, the employer did not provide employees performing Class I asbestos abatement work inside of a regulated area (containment area) with a full-face powered air-purifying respirator or a supplied air respirator.  Employees had performed removal, demolition and cleanup of textured ceiling covering which contained asbestos while wearing standard full-face air-purifying respirators.  A negative exposure assessment had not been conducted for these employees and was not used as the basis for respirator selection.      Abatement Note:  Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (O) $1800
  • — Z (S) $1800

1926.1101 G05 I B 2

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Sep 28, 2012
Abate by
Oct 1, 2012
Penalty
Initial $1,800 · Current $0 Reduced
29 CFR 1926.1101(g)(5)(i)[B][2]:  Electrical circuits in the enclosure shall be deactivated, unless equipped with ground-fault circuit interrupters:    a)  On or about July 20, 2012, and at times prior, employees were exposed to electrical shock hazards while they worked inside an asbestos abatement enclosure in which all electrical circuits had not been deactivated or equipped with a ground-fault interrupter.        Abatement Note:  Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).